Abstract back to ToC

The Fire Safety Ontology (FiSa) enables the classification of buildings and its components based on fire safety considerations. FiSa establish a fire safety perspective for buildings utilizing a combination of building codes, technical regulations, guidelines, and semi-structured interviews with fire safety planners. Subsequently, fire safety domain insights from experts were aligned to knowledge about building design from other domains, such as architecture. Through this collaborative effort and the instantiation of building data within the ontology, structural fire safety requirements from regulations were automatically inferred by reasoning with common inference engines, simulating an automatic compliance checking.

Introduction back to ToC

This is a place holder text for the introduction. The introduction should briefly describe the ontology, its motivation, state of the art and goals.

Namespace declarations

Table 1: Namespaces used in the document
fisa<https://purl.org/fisa#>
sw<http://www.w3.org/2003/06/sw-vocab-status/ns>
owl<http://www.w3.org/2002/07/owl>
bot<https://w3id.org/bot>
xsd<http://www.w3.org/2001/XMLSchema>
swrl<http://www.w3.org/2003/11/swrl>
swrlb<http://www.w3.org/2003/11/swrlb>
skos<http://www.w3.org/2004/02/skos/core>
rdfs<http://www.w3.org/2000/01/rdf-schema>
swrla<http://swrl.stanford.edu/ontologies/3.3/swrla.owl>
rdf<http://www.w3.org/1999/02/22-rdf-syntax-ns>
xml<http://www.w3.org/XML/1998/namespace>
dcterms<http://purl.org/dc/terms>
vann<http://purl.org/vocab/vann>

Fire Safety Ontology (FiSa): Overview back to ToC

This ontology has the following classes and properties.

Classes

Object Properties

Data Properties

Annotation Properties

Named Individuals

Cross-reference for Fire Safety Ontology (FiSa) classes, object properties and data properties back to ToC

This section provides details for each class and property defined by Fire Safety Ontology (FiSa).

Classes

AboveGroundStoreyc back to ToC or Class ToC

IRI: https://purl.org/fisa#AboveGroundStorey

Is defined by
https://purl.org/fisa#MBO
has super-classes
Storey c
has sub-classes
GroundStorey c, UpperStorey c
is disjoint with
Basement c

AccessibilityOfFireFightersc back to ToC or Class ToC

IRI: https://purl.org/fisa#AccessibilityOfFireFighters

has super-classes
SiteDevelopmentMeasure c
is disjoint with
AreaForFireFighters c, ConstructionalMovingArea c, ExtinguishingWaterAccess c, FireFighterAccess_Entrance c, FireFighterAccessPoint c, InstallationArea c

Accommodationc back to ToC or Class ToC

IRI: https://purl.org/fisa#Accommodation

§2 (4) 8. MBO (parts) 'accommodations with more than 12 beds,'
Is defined by
https://purl.org/fisa#MBeVO
has super-classes
SpecialPurposeCondition c

AccommodationFacilityc back to ToC or Class ToC

IRI: https://purl.org/fisa#AccommodationFacility

§2 (4) 11. MBO Other facilities for lodging individuals, including dormitories.
has super-classes
SpecialPurposeCondition c

Administrativec back to ToC or Class ToC

IRI: https://purl.org/fisa#Administrative

has super-classes
SpaceUsage c
has members
Administrative ni
is also defined as
named individual

Agriculturec back to ToC or Class ToC

IRI: https://purl.org/fisa#Agriculture

has super-classes
UtilizationPurpose c
has members
Agriculture ni
is also defined as
named individual

AmusementParkc back to ToC or Class ToC

IRI: https://purl.org/fisa#AmusementPark

Venue designed for entertainment and leisure.
has super-classes
SpecialPurposeCondition c

AnimalHusbandryc back to ToC or Class ToC

IRI: https://purl.org/fisa#AnimalHusbandry

has super-classes
UtilizationPurpose c
has members
AnimalHusbandry ni
is also defined as
named individual

Anteroomc back to ToC or Class ToC

IRI: https://purl.org/fisa#Anteroom

An anteroom refers to an area within a building that is used to act as a buffer zone between different rooms or areas. For example, an anteroom can be used to delay or prevent the entry of smoke, fire, or contaminants from one area into another.
has super-classes
Space c
is disjoint with
Elevator c, FireFighterLift c, NecessaryCorridor c, NecessaryStairSpace c, ResidenceSpace c, SafetyStairSpace c, SecurityGate c, SpaceOfIncreasedFireRisk c, StairSpaceExtension c

Apronc back to ToC or Class ToC

IRI: https://purl.org/fisa#Apron

A structural or building device used to cover or protect a specific area or opening.
has super-classes
WallParts c
is disjoint with
Parapet c, Profile c

ArcadeSpacec back to ToC or Class ToC

IRI: https://purl.org/fisa#ArcadeSpace

§2 (4) 8. MBO (parts) 'gambling halls larger than 150 square meters.'
has super-classes
SpecialPurposeCondition c

AreaForFireFightersc back to ToC or Class ToC

IRI: https://purl.org/fisa#AreaForFireFighters

has super-classes
SiteDevelopmentMeasure c
is disjoint with
AccessibilityOfFireFighters c, ConstructionalMovingArea c, ExtinguishingWaterAccess c, FireFighterAccess_Entrance c, FireFighterAccessPoint c, InstallationArea c

AssemblyBuildingc back to ToC or Class ToC

IRI: https://purl.org/fisa#AssemblyBuilding

§2 (4) 7. MBO 'a) With assembly rooms collectively accommodating more than 200 visitors and sharing common escape routes b) Outdoors, with stage areas or open sports facilities including stands, totaling more than 1,000 visitors, excluding temporary structures'
Is defined by
https://purl.org/fisa#MVStättVO
has super-classes
SpecialPurposeCondition c

AssemblyProductc back to ToC or Class ToC

IRI: https://purl.org/fisa#AssemblyProduct

Construction product for merging or assembling.
has super-classes
BuildingElement c
has sub-classes
Fastening c, JointSealing c, Posts c, Transom c
is disjoint with
Cladding c, Closing c, Installation c, Insulation c, Roof c, Roofing c, Slab c, Stairs c, StairsParts c, SystemFlooring c, Wall c, WallParts c

AssessmentBasisc back to ToC or Class ToC

IRI: https://purl.org/fisa#AssessmentBasis

Describes the documents that a fire safety professional consults to prepare a fire safety certificate.
has sub-classes
ClientSpecification c, GeneralInformation c, PlanningDocument c, RuleOfApplication c
is in range of
hasAssessmentBasis op

AtticSpacec back to ToC or Class ToC

IRI: https://purl.org/fisa#AtticSpace

By definition, the upper edge of the roof space, is the lower edge of the roof.
has super-classes
Zone c
is in domain of
isUsable dp
has members
geb03 dachraum ni
is disjoint with
CavitySpace c, FireCompartment c, SmokeCompartment c, StructuralFacility c, Surrounding c, UtilizationUnit c, Site c, Space c, Storey c

Basementc back to ToC or Class ToC

IRI: https://purl.org/fisa#Basement

Is defined by
https://purl.org/fisa#MBO
has super-classes
Storey c
is disjoint with
AboveGroundStorey c

Bathroomc back to ToC or Class ToC

IRI: https://purl.org/fisa#Bathroom

has super-classes
SpaceUsage c
has members
Bathroom ni
is also defined as
named individual

Buildingc back to ToC or Class ToC

IRI: https://w3id.org/bot#Building

An independent unit of the built environment with a characteristic spatial structure, intended to serve at least one function or user activity [ISO 12006-2:2013]. A bot:Building is a part of the physical world or a virtual world that is inherently both located in this world and having a 3D spatial extent, is contained in a building site, and can contain one or more storeys that are vertically connected.
Is defined by
http://www.systemsEngineering.org/isabellefitkau/fisa.owl#MBO
has super-classes
StructuralFacility c
has sub-classes
SpecialPurposeConstruction c, StandardConstruction c
is in range of
hasBuilding op
has members
Building02 ni, Building03 ni, Building04 ni, Building05 ni, Building06_(Assembly) ni, Building07_(SalesPremises) ni, Building08_(LayerSystem) ni, Building1a ni, Building1b ni
is disjoint with
Garage c

BuildingClassc back to ToC or Class ToC

IRI: https://purl.org/fisa#BuildingClass

Categorization of buildings based on certain characteristics such as use, size, height, and functional requirements.
Is defined by
https://purl.org/fisa#MBO
has super-classes
Classification c
has sub-classes
BuildingClass1 c, BuildingClass2 c, BuildingClass3 c, BuildingClass4 c, BuildingClass5 c
is in range of
hasBuildingClass op
is disjoint with
BuildingMaterialClass c

BuildingClass1c back to ToC or Class ToC

IRI: https://purl.org/fisa#BuildingClass1

Buildings are divided into the following building classes: 1. building class 1: (a) freestanding/detached buildings not exceeding 7 m in height and not more than two units of use not exceeding 400 m2 in total; and (b) freestanding/detached agricultural or forestry buildings, [...]
Is defined by
https://purl.org/fisa#MBO
has super-classes
BuildingClass c
has sub-classes
BuildingClass1a c, BuildingClass1b c
is disjoint with
BuildingClass2 c, BuildingClass3 c, BuildingClass4 c, BuildingClass5 c

BuildingClass1ac back to ToC or Class ToC

IRI: https://purl.org/fisa#BuildingClass1a

has super-classes
BuildingClass1 c
has members
BuildingClass1a ni
is disjoint with
BuildingClass1b c
is also defined as
named individual

BuildingClass1bc back to ToC or Class ToC

IRI: https://purl.org/fisa#BuildingClass1b

has super-classes
BuildingClass1 c
has members
BuildingClass1b ni
is disjoint with
BuildingClass1a c
is also defined as
named individual

BuildingClass2c back to ToC or Class ToC

IRI: https://purl.org/fisa#BuildingClass2

has super-classes
BuildingClass c
has members
BuildingClass2 ni
is disjoint with
BuildingClass1 c, BuildingClass3 c, BuildingClass4 c, BuildingClass5 c
is also defined as
named individual

BuildingClass3c back to ToC or Class ToC

IRI: https://purl.org/fisa#BuildingClass3

has super-classes
BuildingClass c
has members
BuildingClass3 ni
is disjoint with
BuildingClass1 c, BuildingClass2 c, BuildingClass4 c, BuildingClass5 c
is also defined as
named individual

BuildingClass4c back to ToC or Class ToC

IRI: https://purl.org/fisa#BuildingClass4

has super-classes
BuildingClass c
has members
BuildingClass4 ni
is disjoint with
BuildingClass1 c, BuildingClass2 c, BuildingClass3 c, BuildingClass5 c
is also defined as
named individual

BuildingClass5c back to ToC or Class ToC

IRI: https://purl.org/fisa#BuildingClass5

has super-classes
BuildingClass c
has members
BuildingClass5 ni
is disjoint with
BuildingClass1 c, BuildingClass2 c, BuildingClass3 c, BuildingClass4 c
is also defined as
named individual

BuildingMaterialClassc back to ToC or Class ToC

IRI: https://purl.org/fisa#BuildingMaterialClass

Is used to ensure the extension for the fire safety properties. Thus, in addition to the properties of the building regulatory specifications already specified in fisa:StructuralFireSafetyRequirements", the building material classes according to DIN 4102-1 and also the harmonized technical specifications with their additional performance parameters according to e.g. DIN EN 13501-2 can be incorporated. More detailed information can also be found in the MVVTB.
Is defined by
https://purl.org/fisa#DIN4102-1:1998-05
has super-classes
Classification c
is in range of
hasBuildingMaterialClass op
is disjoint with
BuildingClass c

Campsitec back to ToC or Class ToC

IRI: https://purl.org/fisa#Campsite

Outdoor areas equipped for recreational use for camping activities.
has super-classes
SpecialPurposeCondition c

Canteenc back to ToC or Class ToC

IRI: https://purl.org/fisa#Canteen

has super-classes
SpaceUsage c
has members
Canteen ni
is also defined as
named individual

Carec back to ToC or Class ToC

IRI: https://purl.org/fisa#Care

has super-classes
UtilizationPurpose c
has members
Care ni
is also defined as
named individual

CareForPeoplec back to ToC or Class ToC

IRI: https://purl.org/fisa#CareForPeople

has super-classes
UtilizationPurpose c
has members
CareForPeople ni
is also defined as
named individual

CavitySpacec back to ToC or Class ToC

IRI: https://purl.org/fisa#CavitySpace

Is defined by
https://purl.org/fisa#MBO
has super-classes
Zone c
is in range of
hasCavity op
is disjoint with
AtticSpace c, FireCompartment c, SmokeCompartment c, StructuralFacility c, Surrounding c, UtilizationUnit c, Site c, Space c, Storey c

ChildCarec back to ToC or Class ToC

IRI: https://purl.org/fisa#ChildCare

has super-classes
UtilizationPurpose c
has members
ChildCare ni
is also defined as
named individual

Claddingc back to ToC or Class ToC

IRI: https://purl.org/fisa#Cladding

Application of fire-resistant materials or coatings to structural elements such as beams, columns, walls or ceilings. This cladding serves to improve the fire resistance and fire protection properties of these structural elements, thus slowing down the spread of fire and smoke.
has super-classes
BuildingElement c
is disjoint with
AssemblyProduct c, Closing c, Installation c, Insulation c, Roof c, Roofing c, Slab c, Stairs c, StairsParts c, SystemFlooring c, Wall c, WallParts c

Classificationc back to ToC or Class ToC

IRI: https://purl.org/fisa#Classification

The classification of building elements, materials, buildings or systems into different classes or categories based on certain established criteria. These classifications are used to establish standards, structure information, and establish uniform rules or requirements for various aspects of construction.
has super-classes
has sub-classes
BuildingClass c, BuildingMaterialClass c
is in domain of
isClassificationOf op

ClientSpecificationc back to ToC or Class ToC

IRI: https://purl.org/fisa#ClientSpecification

Specifications from the building owner can have a significant influence on fire safety, e.g. by providing information on the utilization concept.
has super-classes
AssessmentBasis c
is disjoint with
GeneralInformation c, PlanningDocument c, RuleOfApplication c

ClosedProfilec back to ToC or Class ToC

IRI: https://purl.org/fisa#ClosedProfile

Wall profile with a closed shape.
is equivalent to
Profile c and (isClosedProfile dp value true)
has super-classes
Profile c
has members
B08_ClosedProfile01 ni, B08_ClosedProfile02 ni
is disjoint with
OpenProfile c

Closingc back to ToC or Class ToC

IRI: https://purl.org/fisa#Closing

The proper termination or covering of openings or penetrations in buildings to prevent the spread of fire, smoke, and toxic gases between different rooms or sections.
has super-classes
BuildingElement c
has sub-classes
Door c, FireDamper c, Gate c, Glazing c, Window c
is disjoint with
AssemblyProduct c, Cladding c, Installation c, Insulation c, Roof c, Roofing c, Slab c, Stairs c, StairsParts c, SystemFlooring c, Wall c, WallParts c

Combustion appliances are fixed installations or equipment used in or on buildings and intended to generate heat by combustion.c back to ToC or Class ToC

IRI: https://purl.org/fisa#CombustionAppliance

Is defined by
https://purl.org/fisa#MBO
has super-classes
Component c
is disjoint with
Opening c, Structure c, SurfaceType c, TechnicalComponent c, BuildingElement c

CompartmentWallc back to ToC or Class ToC

IRI: https://purl.org/fisa#CompartmentWall

A space-enclosing structural member of a space or utilization units of use within storeys.
has super-classes
Wall c
is disjoint with
DriveShaftWall c, ExternalWall c, FireWall c, WallOfANecessaryCorridor c, WallOfANecessaryStaircase c

ComponentTypec back to ToC or Class ToC

IRI: https://purl.org/fisa#ComponentType

Component types are used for extended categorization of components.
has sub-classes
FireResistantEnclosure c, LoadbearingEnclosingComponent c, LoadbearingNonEnclosingComponent c, NonLoadbearingEnclosingComponent c, NonLoadbearingNonEnclosingComponent c, PositionAccessibleForFireService c
is in range of
hasComponentType op

ConstructionalMovingAreac back to ToC or Class ToC

IRI: https://purl.org/fisa#ConstructionalMovingArea

has super-classes
SiteDevelopmentMeasure c
is disjoint with
AccessibilityOfFireFighters c, AreaForFireFighters c, ExtinguishingWaterAccess c, FireFighterAccess_Entrance c, FireFighterAccessPoint c, InstallationArea c

Corridorc back to ToC or Class ToC

IRI: https://purl.org/fisa#Corridor

has super-classes
SpaceUsage c
has members
Corridor ni
is also defined as
named individual

DayCareCenterc back to ToC or Class ToC

IRI: https://purl.org/fisa#DayCareCenter

§2 (4) 12. MBO Daycare facilities for children, people with disabilities, and the elderly, excluding those accommodating no more than ten children, including day care.
has super-classes
SpecialPurposeCondition c

DefensiveFireSafetyc back to ToC or Class ToC

IRI: https://purl.org/fisa#DefensiveFireSafety

Defensive fire safety includes all passive and active measures taken by the fire department and other emergency services before and during a fire incident.
has super-classes
FireSafety c
is disjoint with
OrganizationalFireSafety c, StructuralFireSafety c, TechnicalFireSafety c

DIN4102c back to ToC or Class ToC

IRI: https://purl.org/fisa#DIN4102

has super-classes
Norm c
has sub-classes
DIN4102-12:1998-11 c, DIN4102-15:1990-05 c, DIN4102-17:2017-12 c, DIN4102-1:1998-05 c

DIN4102-12:1998-11c back to ToC or Class ToC

IRI: https://purl.org/fisa#DIN4102-12:1998-11

has super-classes
DIN4102 c
is disjoint with
DIN4102-15:1990-05 c, DIN4102-17:2017-12 c, DIN4102-1:1998-05 c

DIN4102-15:1990-05c back to ToC or Class ToC

IRI: https://purl.org/fisa#DIN4102-15:1990-05

has super-classes
DIN4102 c
is disjoint with
DIN4102-12:1998-11 c, DIN4102-17:2017-12 c, DIN4102-1:1998-05 c

DIN4102-17:2017-12c back to ToC or Class ToC

IRI: https://purl.org/fisa#DIN4102-17:2017-12

has super-classes
DIN4102 c
is disjoint with
DIN4102-12:1998-11 c, DIN4102-15:1990-05 c, DIN4102-1:1998-05 c

DIN4102-1:1998-05c back to ToC or Class ToC

IRI: https://purl.org/fisa#DIN4102-1:1998-05

has super-classes
DIN4102 c
is disjoint with
DIN4102-12:1998-11 c, DIN4102-15:1990-05 c, DIN4102-17:2017-12 c

DIN_EN_13501c back to ToC or Class ToC

IRI: https://purl.org/fisa#DIN_EN13501

Classification of construction products and types of construction for their fire behavior.
has super-classes
Eurocode c

Doorc back to ToC or Class ToC

IRI: https://purl.org/fisa#Door

A movable device or closure of an opening in a building wall or structure used to provide or restrict access for persons, goods, or vehicles.
has super-classes
Closing c
is disjoint with
FireDamper c, Gate c, Glazing c, Window c

Dormitoryc back to ToC or Class ToC

IRI: https://purl.org/fisa#Dormitory

§2 (4) 11. MBO 'Other facilities for lodging individuals, including dormitories'
has super-classes
SpecialPurposeCondition c

DriveShaftWallc back to ToC or Class ToC

IRI: https://purl.org/fisa#DriveShaftWall

Elevators inside buildings must have their own drive shafts to prevent fire spread to other floors for a sufficient length of time.
has super-classes
Wall c
is disjoint with
CompartmentWall c, ExternalWall c, FireWall c, WallOfANecessaryCorridor c, WallOfANecessaryStaircase c

Educationc back to ToC or Class ToC

IRI: https://purl.org/fisa#Education

has super-classes
UtilizationPurpose c
has members
Education ni
is also defined as
named individual

EducationalInstitutionc back to ToC or Class ToC

IRI: https://purl.org/fisa#EducationalInstitution

Establishments dedicated to learning.
has super-classes
SpecialPurposeCondition c

Elevatorc back to ToC or Class ToC

IRI: https://purl.org/fisa#Elevator

An elevator refers to a space for a device for the vertical or inclined transportation of persons or goods between different levels of a building.
has super-classes
Space c
is disjoint with
Anteroom c, FireFighterLift c, NecessaryCorridor c, NecessaryStairSpace c, ResidenceSpace c, SafetyStairSpace c, SecurityGate c, SpaceOfIncreasedFireRisk c, StairSpaceExtension c

EmergencyMedicalServicec back to ToC or Class ToC

IRI: https://purl.org/fisa#EmergencyMedicalService

has super-classes
UtilizationPurpose c
has members
EmergencyMedicalService ni
is also defined as
named individual

EscapeRoutec back to ToC or Class ToC

IRI: https://purl.org/fisa#EscapeRoute

Escape routes (as in rescue) in the strict sense are accesses and routes for emergency services such as the fire department, via which the rescue (= external rescue) of e.g. injured persons and animals as well as fire fighting (extinguishing work) are possible. (see also §14 MBO) Escape routes are routes, e.g. corridors, staircases and exits to the outside, via which people and animals can leave structural facilities in the event of danger (in the event of fire) and bring themselves to safety (= self-rescue). In general, the two terms are combined in the building regulations under the escape route.
has super-classes
FireSafety c
has sub-classes
FirstEscapeRoute c, SecondEscapeRoute c

Eurocodec back to ToC or Class ToC

IRI: https://purl.org/fisa#Eurocode

Eurocodes are fundamental European standards to be applied as unified design rules in civil engineering and structural design.
has super-classes
RuleOfApplication c
has sub-classes
DIN_EN_13501 c
is disjoint with
GeneralPrescription c, Norm c

ExternalDevelopmentc back to ToC or Class ToC

IRI: https://purl.org/fisa#ExternalDevelopment

has super-classes
Site c, UtilizationPurpose c
has members
ExternalDevelopment ni
is also defined as
named individual

ExternalWallc back to ToC or Class ToC

IRI: https://purl.org/fisa#ExternalWall

A wall that forms the outer boundary and protects the building from environmental factors such as weather, wind, moisture and temperature fluctuations.
is equivalent to
isExternal dp value true
has super-classes
Wall c
has members
B08_ExternalWall01 ni
is disjoint with
CompartmentWall c, DriveShaftWall c, FireWall c, WallOfANecessaryCorridor c, WallOfANecessaryStaircase c

ExtinguishingWaterAccessc back to ToC or Class ToC

IRI: https://purl.org/fisa#ExtinguishingWaterAccess

has super-classes
SiteDevelopmentMeasure c
has sub-classes
ExtinguishingWaterRetention c, ExtinguishingWaterSupply c
is disjoint with
AccessibilityOfFireFighters c, AreaForFireFighters c, ConstructionalMovingArea c, FireFighterAccess_Entrance c, FireFighterAccessPoint c, InstallationArea c

ExtinguishingWaterRetentionc back to ToC or Class ToC

IRI: https://purl.org/fisa#ExtinguishingWaterRetention

has super-classes
ExtinguishingWaterAccess c
is disjoint with
ExtinguishingWaterSupply c

ExtinguishingWaterSupplyc back to ToC or Class ToC

IRI: https://purl.org/fisa#ExtinguishingWaterSupply

has super-classes
ExtinguishingWaterAccess c
is disjoint with
ExtinguishingWaterRetention c

Fasteningc back to ToC or Class ToC

IRI: https://purl.org/fisa#Fastening

Building elements used to securely connect or anchor together various components of a building or structure.
has super-classes
AssemblyProduct c
has members
B08_Fastening ni
is disjoint with
JointSealing c, Posts c, Transom c

FireBehaviourc back to ToC or Class ToC

IRI: https://purl.org/fisa#FireBehaviour

Building materials are differentiated according to the requirements for their fire behavior, such as their combustibility and flammability.
is equivalent to
{ flammable , highly-flammable , non-flammable , normal-flammable , retardent-flammable }
has super-classes
StructuralFireSafetyMeasures c
is in domain of
isMoreFlammableThan op
is in range of
hasFireBehaviour op, isMoreFlammableThan op, isPermittedWithFireBehaviour op
has members
flammable ni, highly-flammable ni, non-flammable ni, normal-flammable ni, retardent-flammable ni
is disjoint with
FireResistance c, SpaceClosure c

FireBrigadeLiftsc back to ToC or Class ToC

IRI: https://purl.org/fisa#FireBrigadeLifts

Firefighters' elevators are specially secured elevators that allow firefighters to reach the fire storeys in case of fire.
has super-classes
TechnicalComponent c
is disjoint with
FireControl_of_Lifts c, HeatExtractionDevice c, LightningSafetySystem c, ObjectRadioSystem_for_FireBrigade c

FireCompartmentc back to ToC or Class ToC

IRI: https://purl.org/fisa#FireCompartment

A fire compartment is a structurally demarcated area that burns out as intended in the event of damage and thus must not allow fire to spread to other fire compartments.
has super-classes
Zone c
is in range of
hasFireCompartment op
is disjoint with
AtticSpace c, CavitySpace c, SmokeCompartment c, StructuralFacility c, Surrounding c, UtilizationUnit c, Site c, Space c, Storey c

FireControl_of_Liftsc back to ToC or Class ToC

IRI: https://purl.org/fisa#FireControlOfLifts

The fire control of lifts is intended to prevent the elevator from continuing to be used as a means of movement in the event of a detected fire (hazard) in a building.
has super-classes
TechnicalComponent c
is disjoint with
FireBrigadeLifts c, HeatExtractionDevice c, LightningSafetySystem c, ObjectRadioSystem_for_FireBrigade c

FireDamperc back to ToC or Class ToC

IRI: https://purl.org/fisa#FireDamper

In the event of a fire, they are used to close off openings in penetrations relevant to fire safety, such as ventilation or cable shafts, thus preventing the spread of fire and smoke.
has super-classes
Closing c
is disjoint with
Door c, Gate c, Glazing c, Window c

FireFighterAccess_Entrancec back to ToC or Class ToC

IRI: https://purl.org/fisa#FireFighterAccessEntrance

has super-classes
SiteDevelopmentMeasure c
is disjoint with
AccessibilityOfFireFighters c, AreaForFireFighters c, ConstructionalMovingArea c, ExtinguishingWaterAccess c, FireFighterAccessPoint c, InstallationArea c

FireFighterAccessPointc back to ToC or Class ToC

IRI: https://purl.org/fisa#FireFighterAccessPoint

has super-classes
SiteDevelopmentMeasure c
is disjoint with
AccessibilityOfFireFighters c, AreaForFireFighters c, ConstructionalMovingArea c, ExtinguishingWaterAccess c, FireFighterAccess_Entrance c, InstallationArea c

FireFighterLiftc back to ToC or Class ToC

IRI: https://purl.org/fisa#FireFighterLift

Firefighters' elevators are specially secured elevators that can also be used in the event of a fire - primarily by the fire department.
has super-classes
Space c
is disjoint with
Anteroom c, Elevator c, NecessaryCorridor c, NecessaryStairSpace c, ResidenceSpace c, SafetyStairSpace c, SecurityGate c, SpaceOfIncreasedFireRisk c, StairSpaceExtension c

FireResistancec back to ToC or Class ToC

IRI: https://purl.org/fisa#FireResistance

Building components are differentiated according to their fire resistance requirements, i.e. the duration during which a component retains its function in the event of a standard fire/fire according to norm bzw. testing standards.
is equivalent to
{ fire-resistant , fire-retardent , highly-fire-resistant , highly-fire-retardent , mosthighly-fire-resistant }
has super-classes
StructuralFireSafetyMeasures c
is in domain of
isMoreFireResistantThan op
is in range of
hasFireResistance op, hasRequirementOfFireResistance op, isMoreFireResistantThan op, isPermittedWithFireResistance op
has members
fire-resistant ni, fire-retardent ni, highly-fire-resistant ni, highly-fire-retardent ni, mosthighly-fire-resistant ni
is disjoint with
FireBehaviour c

FireResistantEnclosurec back to ToC or Class ToC

IRI: https://purl.org/fisa#FireResistantEnclosure

Fire resistant enclosures are either opened manually and always close automatically or are normally held open and close themselves in case of fire or smoke.en
is equivalent to
(((hasFireResistance op some FireResistance c) and (isSelfClosing dp value true) and (isSmokeResistant dp value true)) and (Door c or FireDamper c or Gate c)) or (((hasFireResistance op some FireResistance c) and (isSelfClosing dp value true) and (isTightClosing dp value true)) and (Door c or FireDamper c or Gate c))
has super-classes
ComponentType c
is disjoint with
LoadbearingEnclosingComponent c, LoadbearingNonEnclosingComponent c, NonLoadbearingEnclosingComponent c, NonLoadbearingNonEnclosingComponent c, PositionAccessibleForFireService c

FireSafetyc back to ToC or Class ToC

IRI: https://purl.org/fisa#FireSafety

Fire safety refers to all measures that prevent the development and spread of a fire and enable the rescue of people and animals as well as effective extinguishing work in the event of a fire.
has sub-classes
DefensiveFireSafety c, EscapeRoute c, OrganizationalFireSafety c, RescueConcept c, SiteDevelopmentMeasure c, StructuralFireSafety c, TechnicalFireSafety c

FireSafetyCertificatec back to ToC or Class ToC

IRI: https://purl.org/fisa#FireSafetyCertificate

A document prepared by professionals such as fire safety professionals, to confirm compliance with fire safety requirements and standards/regulations for a building project.
has super-classes
TechnicalStructuralCertificate c
has sub-classes
PrescriptiveCertificate c, ProtectiveGoalOrientedCertificate c
is disjoint with
OtherCertificate c

FireWallc back to ToC or Class ToC

IRI: https://purl.org/fisa#FireWall

Firewalls must be used as room-enclosing components to close off buildings (fire wall as external wall) or to divide buildings into fire compartments (internal fire wall) and must be long enough to prevent the spread of fire to other buildings or fire compartments.
Is defined by
https://purl.org/fisa#MBO
has super-classes
Wall c
has sub-classes
FireWallAsExternalWall c, InternalFireWall c, WallinsteadOfFireWall c
is disjoint with
CompartmentWall c, DriveShaftWall c, ExternalWall c, WallOfANecessaryCorridor c, WallOfANecessaryStaircase c

FireWallAsExternalWallc back to ToC or Class ToC

IRI: https://purl.org/fisa#FireWallAsExternalWall

to: §30 (2) 1. and 4. Fire walls are required 1. As an external wall, except for buildings without living quarters and without fireplaces with no more than 50 m3 gross volume, if these external walls are erected at or with a distance of less than 2.50 m from the property boundary, unless a distance of at least 5 m from existing buildings or future buildings permitted under the building regulations is ensured, [...] 4. as an external wall between residential buildings and attached agricultural buildings, as well as an internal fire wall between the residential part and the agricultural part of a building.
Is defined by
https://purl.org/fisa#
https://purl.org/fisa#
has super-classes
FireWall c
is disjoint with
InternalFireWall c, WallinsteadOfFireWall c

FirstEscapeRoutec back to ToC or Class ToC

IRI: https://purl.org/fisa#FirstEscapeRoute

The first escape route must always be structural (a permanently existing fixed structural facility) and serve self-rescue.
has super-classes
EscapeRoute c
has members
B06_FirstEscapeRoute ni
is disjoint with
SecondEscapeRoute c

Foyerc back to ToC or Class ToC

IRI: https://purl.org/fisa#Foyer

has super-classes
SpaceUsage c
has members
Foyer ni
is also defined as
named individual

Garagec back to ToC or Class ToC

IRI: https://purl.org/fisa#Garage

Exception from §2 (7) S3 MBO: Showrooms, salesrooms, workshops and storage rooms for motor vehicles are not parking spaces or garages.
Is defined by
https://purl.org/fisa#MBO
has super-classes
StructuralFacility c
is disjoint with
Building c

Gatec back to ToC or Class ToC

IRI: https://purl.org/fisa#Gate

A large, movable device or closure of an opening in a building wall or structure used to provide or restrict access for persons, vehicles, or goods.
has super-classes
Closing c
has members
tor01 ni, tor02 ni
is disjoint with
Door c, FireDamper c, Glazing c, Window c

GeneralAdministrativeRegulationc back to ToC or Class ToC

IRI: https://purl.org/fisa#MusterVerwaltungsvorschrift

Administrative regulations are abstract-general rules issued by the administration for the administration, i.e. rules that the administration issues itself.
has super-classes
GeneralPrescription c
has sub-classes
MVV_TB c, M_FIBauVwV c

GeneralGuidelinec back to ToC or Class ToC

IRI: https://purl.org/fisa#Musterrichtlinie

A guideline is a legal act in which a goal to be achieved by all countries/counties is specified. However, it is up to the individual countries/counties to enact their own legislation to achieve this goal.
has super-classes
GeneralPrescription c

GeneralInformationc back to ToC or Class ToC

IRI: https://purl.org/fisa#GeneralInformation

Contains information on dimensions, construction type, location and use of the building in the fire safety certificate.
has super-classes
AssessmentBasis c
is disjoint with
ClientSpecification c, PlanningDocument c, RuleOfApplication c

GeneralPrescriptionc back to ToC or Class ToC

IRI: https://purl.org/fisa#Mustervorschrift

has super-classes
RuleOfApplication c
has sub-classes
GeneralAdministrativeRegulation c, GeneralGuideline c, MBO c, SpecialPurposePrescription c
is disjoint with
Eurocode c, Norm c

GeneralSlabc back to ToC or Class ToC

IRI: https://purl.org/fisa#GeneralSlab

A slab that is not a storey slab.
is equivalent to
isStoreySlab dp value false
has super-classes
Slab c
is disjoint with
StoreySlab c

Glazingc back to ToC or Class ToC

IRI: https://purl.org/fisa#Glazing

The use of glass as a construction material to create transparent elements such as windows, doors or other glass surfaces in buildings.
has super-classes
Closing c
is disjoint with
Door c, FireDamper c, Gate c, Window c

GroundStoreyc back to ToC or Class ToC

IRI: https://purl.org/fisa#GroundStorey

has super-classes
AboveGroundStorey c
has members
B07_GroundStorey ni
is disjoint with
UpperStorey c

Gymc back to ToC or Class ToC

IRI: https://purl.org/fisa#Gym

has super-classes
SpaceUsage c
has members
Gym ni
is also defined as
named individual

HazardousEnvironmentc back to ToC or Class ToC

IRI: https://purl.org/fisa#HazardousEnvironment

has super-classes
UtilizationPurpose c
has members
HazardousEnvironment ni
is also defined as
named individual

HeatExtractionDevicec back to ToC or Class ToC

IRI: https://purl.org/fisa#HeatExtractionDevice

These components dissipate heat/hot smoke gases in the event of a fire to ensure a smoke-free area near the floor and on escape routes.
has super-classes
TechnicalComponent c
is disjoint with
FireBrigadeLifts c, FireControl_of_Lifts c, LightningSafetySystem c, ObjectRadioSystem_for_FireBrigade c

HighRiseBuildingc back to ToC or Class ToC

IRI: https://purl.org/fisa#HighRiseBuilding

§2 (4) 1. MBO 'Buildings with a height surpassing 22 meters as specified in Section 3, Clause 2.' _ Note: The height being the average height.
Is defined by
https://purl.org/fisa#MHHR
is equivalent to
hasAverageHeight dp some
has super-classes
SpecialPurposeCondition c

Hospitalc back to ToC or Class ToC

IRI: https://purl.org/fisa#Hospital

Medical facilities designed for diagnosing and treating patients, often equipped with medical technology and specialized personnel.
has super-classes
SpecialPurposeCondition c

Hospitalityc back to ToC or Class ToC

IRI: https://purl.org/fisa#Hospitality

has super-classes
UtilizationPurpose c
has members
Hospitality ni
is also defined as
named individual

Installationc back to ToC or Class ToC

IRI: https://purl.org/fisa#Installation

Facilities or structures intended for the installation of technical supply lines, such as electrical cables, data lines, pipelines for water, gas or heating.
has super-classes
BuildingElement c
has sub-classes
InstallationDuct c, InstallationShaft c
is disjoint with
AssemblyProduct c, Cladding c, Closing c, Insulation c, Roof c, Roofing c, Slab c, Stairs c, StairsParts c, SystemFlooring c, Wall c, WallParts c

InstallationAreac back to ToC or Class ToC

IRI: https://purl.org/fisa#InstallationArea

has super-classes
SiteDevelopmentMeasure c
is disjoint with
AccessibilityOfFireFighters c, AreaForFireFighters c, ConstructionalMovingArea c, ExtinguishingWaterAccess c, FireFighterAccess_Entrance c, FireFighterAccessPoint c

InstallationDuctc back to ToC or Class ToC

IRI: https://purl.org/fisa#InstallationDuct

Installation ducts are used to protect technical supply lines from damage and external influences.
has super-classes
Installation c
is disjoint with
InstallationShaft c

InstallationShaftc back to ToC or Class ToC

IRI: https://purl.org/fisa#InstallationShaft

By using installation shafts, lines can be routed together from storey to storey through a building over several floors.
has super-classes
Installation c
is disjoint with
InstallationDuct c

Institutionc back to ToC or Class ToC

IRI: https://purl.org/fisa#Institution

has super-classes
UtilizationPurpose c
has members
Institution ni
is also defined as
named individual

Insulationc back to ToC or Class ToC

IRI: https://purl.org/fisa#Insulation

A material used to reduce heat transfer between building components and thus improve the energy efficiency of a building.
has super-classes
BuildingElement c
has members
B08_Insulation01 ni, B08_Insulation02 ni
is disjoint with
AssemblyProduct c, Cladding c, Closing c, Installation c, Roof c, Roofing c, Slab c, Stairs c, StairsParts c, SystemFlooring c, Wall c, WallParts c

Interfacec back to ToC or Class ToC

IRI: https://w3id.org/bot#Interface

A generic concept to qualify the relationship of two or more things in the world, where at least one is a building element or zone. Examples: - Qualification of heat transmission between zones through one or more building elements. This includes one-dimensional (surface) heat losses from one zone to another through a single building element, a two dimensional (line) loss from one zone to another through the connection in which the two elements meet or a three dimensional (point) loss from one zone to another through the connection where three elements (typically two walls and a slab) meet. - Connection of an electric device to the electric system of a building. - A door between one room and another.
is in domain of
interfaceOf op

InternalFireWallc back to ToC or Class ToC

IRI: https://purl.org/fisa#InternalFireWall

To: §30 (2) 2. and 3. Fire walls are required [...] 2. As an internal fire wall for the subdivision of extensive buildings at intervals of no more than 40 m, 3. as an internal fire wall to divide agricultural buildings into fire compartments of not more than 10 000 m3 gross volume, [...]
has super-classes
FireWall c
is disjoint with
FireWallAsExternalWall c, WallinsteadOfFireWall c

JointSealingc back to ToC or Class ToC

IRI: https://purl.org/fisa#JointSealing

Process or technique of sealing joints or gaps between different building elements, materials or surfaces.
has super-classes
AssemblyProduct c
is disjoint with
Fastening c, Posts c, Transom c

Kindergardenc back to ToC or Class ToC

IRI: https://purl.org/fisa#Kindergarden

has super-classes
UtilizationPurpose c
has members
Kindergarden ni
is also defined as
named individual

Kitchenc back to ToC or Class ToC

IRI: https://purl.org/fisa#Kitchen

has super-classes
SpaceUsage c
has members
Kitchen ni
is also defined as
named individual

Labc back to ToC or Class ToC

IRI: https://purl.org/fisa#Lab

has super-classes
UtilizationPurpose c
has members
Lab ni
is also defined as
named individual

LawEnforcementc back to ToC or Class ToC

IRI: https://purl.org/fisa#LawEnforcement

has super-classes
UtilizationPurpose c
has members
LawEnforcement ni
is also defined as
named individual

Leisurec back to ToC or Class ToC

IRI: https://purl.org/fisa#Leisure

has super-classes
UtilizationPurpose c
has members
Leisure ni
is also defined as
named individual

LightningSafetySystemc back to ToC or Class ToC

IRI: https://purl.org/fisa#LightningSafetySystem

Precautions against the harmful effects of lightning strikes on building structures.
has super-classes
TechnicalComponent c
is disjoint with
FireBrigadeLifts c, FireControl_of_Lifts c, HeatExtractionDevice c, ObjectRadioSystem_for_FireBrigade c

LivingRoomc back to ToC or Class ToC

IRI: https://purl.org/fisa#LivingRoom

has super-classes
SpaceUsage c
has members
LivingRoom ni
is also defined as
named individual

LoadbearingEnclosingComponentc back to ToC or Class ToC

IRI: https://purl.org/fisa#LoadbearingEnclosingComponent

Load-bearing, space-enclosing components meet both load-bearing and space-enclosing requirements.
has super-classes
ComponentType c
is disjoint with
FireResistantEnclosure c, LoadbearingNonEnclosingComponent c, NonLoadbearingEnclosingComponent c, NonLoadbearingNonEnclosingComponent c, PositionAccessibleForFireService c

LoadbearingNonEnclosingComponentc back to ToC or Class ToC

IRI: https://purl.org/fisa#LoadbearingNonEnclosingComponent

Load-bearing, non space-enclosing components meet only load-bearing and no space-enclosing requirements.
has super-classes
ComponentType c
is disjoint with
FireResistantEnclosure c, LoadbearingEnclosingComponent c, NonLoadbearingEnclosingComponent c, NonLoadbearingNonEnclosingComponent c, PositionAccessibleForFireService c

M_FIBauRc back to ToC or Class ToC

IRI: https://purl.org/fisa#M_FIBauR

The special purpose construction guideline on portable construction.
has super-classes
SpecialPurposeGuideline c
is disjoint with
MHHR c, MSchulbauR c, MWR c

M_FIBauVwVc back to ToC or Class ToC

IRI: https://purl.org/fisa#M_FIBauVwV

Administrative regulations are abstract-general rules issued by the administration for the administration, i.e. rules that the administration issues itself.
has super-classes
GeneralAdministrativeRegulation c
is disjoint with
MVV_TB c

MBeVOc back to ToC or Class ToC

IRI: https://purl.org/fisa#MBeVO

The special purpose construction regulation on accommodations.
has super-classes
SpecialPurposeRegulation c
is disjoint with
MEltBauVO c, MVKVO c, MVStättVO c

MBOc back to ToC or Class ToC

IRI: https://purl.org/fisa#MBO

-as of August 2023- Use of: Musterbauordnung- version November 2022, last amended 25.09.2020
has super-classes
GeneralPrescription c

MeetingRoomc back to ToC or Class ToC

IRI: https://purl.org/fisa#MeetingRoom

has super-classes
SpaceUsage c
has members
MeetingRoom ni
is also defined as
named individual

MEltBauVOc back to ToC or Class ToC

IRI: https://purl.org/fisa#MEltBauVO

The special purpose construction regulation on the construction and operation for electrical equipment.
has super-classes
SpecialPurposeRegulation c
is disjoint with
MBeVO c, MVKVO c, MVStättVO c

MHHRc back to ToC or Class ToC

IRI: https://purl.org/fisa#MHHR

The special purpose construction guideline on high-rise buildings.
has super-classes
SpecialPurposeGuideline c
is disjoint with
MSchulbauR c, MWR c, M_FIBauR c

MSchulbauRc back to ToC or Class ToC

IRI: https://purl.org/fisa#MSchulbauR

The special purpose construction guideline on school buildings.
has super-classes
SpecialPurposeGuideline c
is disjoint with
MHHR c, MWR c, M_FIBauR c

MVKVOc back to ToC or Class ToC

IRI: https://purl.org/fisa#MVKVO

The special purpose construction regulation on sales premises.
has super-classes
SpecialPurposeRegulation c
is disjoint with
MBeVO c, MEltBauVO c, MVStättVO c

MVStättVOc back to ToC or Class ToC

IRI: https://purl.org/fisa#MVStättVO

The special purpose construction regulation on places of assembly.
has super-classes
SpecialPurposeRegulation c
is disjoint with
MBeVO c, MEltBauVO c, MVKVO c

MVV_TBc back to ToC or Class ToC

IRI: https://purl.org/fisa#MVV_TB

- as of August 2023 - Edition 2023/1 (heard as MVV TB 2022/1)en
has super-classes
GeneralAdministrativeRegulation c
is disjoint with
M_FIBauVwV c

MWRc back to ToC or Class ToC

IRI: https://purl.org/fisa#MWR

The special purpose construction guideline on Residential Facilities.
has super-classes
SpecialPurposeGuideline c
is disjoint with
MHHR c, MSchulbauR c, M_FIBauR c

NecessaryCorridorc back to ToC or Class ToC

IRI: https://purl.org/fisa#NecessaryCorridor

The horizontal escape and rescue route between utilization units and the stairwell or to the outside is called a necessary corridor.
is equivalent to
(hasSpaceUsage op value Corridor) and (isNecessary dp value true)
has super-classes
Space c
is disjoint with
Anteroom c, Elevator c, FireFighterLift c, NecessaryStairSpace c, ResidenceSpace c, SafetyStairSpace c, SecurityGate c, SpaceOfIncreasedFireRisk c, StairSpaceExtension c

NecessaryStairSpacec back to ToC or Class ToC

IRI: https://purl.org/fisa#NecessaryStairSpace

Necessary stairwells are vertically continuous spaces in which one or more stairways may be located that serve to protect a necessary stairway.
is equivalent to
(hasSpaceUsage op value StairSpace) and (isNecessary dp value true)
has super-classes
Space c
is disjoint with
Anteroom c, Elevator c, FireFighterLift c, NecessaryCorridor c, ResidenceSpace c, SafetyStairSpace c, SecurityGate c, SpaceOfIncreasedFireRisk c, StairSpaceExtension c

NonLoadbearingEnclosingComponentc back to ToC or Class ToC

IRI: https://purl.org/fisa#NonLoadbearingEnclosingComponent

Non-load-bearing, space-enclosing components meet no load-bearing, but space-enclosing requirements.
has super-classes
ComponentType c
is disjoint with
FireResistantEnclosure c, LoadbearingEnclosingComponent c, LoadbearingNonEnclosingComponent c, NonLoadbearingNonEnclosingComponent c, PositionAccessibleForFireService c

NonLoadbearingNonEnclosingComponentc back to ToC or Class ToC

IRI: https://purl.org/fisa#NonLoadbearingNonEnclosingComponent

Non-load-bearing, non-space-enclosing components meet neither load-bearing nor space-enclosing requirements.
has super-classes
ComponentType c
is disjoint with
FireResistantEnclosure c, LoadbearingEnclosingComponent c, LoadbearingNonEnclosingComponent c, NonLoadbearingEnclosingComponent c, PositionAccessibleForFireService c

Normc back to ToC or Class ToC

IRI: https://purl.org/fisa#Norm

has super-classes
RuleOfApplication c
has sub-classes
DIN4102 c
is disjoint with
Eurocode c, GeneralPrescription c

NursingHomec back to ToC or Class ToC

IRI: https://purl.org/fisa#NursingHome

§2 (4) 9. MBO 'Buildings with units for care or assistance of individuals with limited self-evacuation capability due to disabilities, if the units: a) Serve more than 6 individuals individually b) Serve individuals requiring intensive care c) Share a common escape route and serve more than 12 individuals collectively'
Is defined by
https://purl.org/fisa#MWR
has super-classes
SpecialPurposeCondition c

ObjectRadioSystem_for_FireBrigadec back to ToC or Class ToC

IRI: https://purl.org/fisa#ObjectRadioSystemForFireBrigade

An object radio system is a stationary radio-technical device for the operational support of the fire department.
has super-classes
TechnicalComponent c
is disjoint with
FireBrigadeLifts c, FireControl_of_Lifts c, HeatExtractionDevice c, LightningSafetySystem c

OfficeRoomc back to ToC or Class ToC

IRI: https://purl.org/fisa#OfficeRoom

has super-classes
SpaceUsage c
has members
OfficeRoom ni
is also defined as
named individual

Openingc back to ToC or Class ToC

IRI: https://purl.org/fisa#Opening

The opening element stands for opening, recess or chase, all reflecting voids. It represents a void within any element that has physical manifestation. [IfcOpeningElement]
Is defined by
https://purl.org/fisa#MBO
has super-classes
Component c
is disjoint with
Combustion appliances are fixed installations or equipment used in or on buildings and intended to generate heat by combustion. c, Structure c, SurfaceType c, TechnicalComponent c, BuildingElement c

OpenProfilec back to ToC or Class ToC

IRI: https://purl.org/fisa#OpenProfile

Wall profile with an open shape.
is equivalent to
Profile c and (isClosedProfile dp value false)
has super-classes
Profile c
is disjoint with
ClosedProfile c

OrganizationalFireSafetyc back to ToC or Class ToC

IRI: https://purl.org/fisa#OrganizationalFireSafety

Organizational fire safety is part of preventive fire safety. Tasks contain: - Maintenance, servicing, use of and correct handling of structural and technical fire protection equipment Marking and keeping clear escape and rescue routes - Posting of fire protection regulations for fire prevention and - for measures to be taken in an emergency (emergency call to the fire department)
has super-classes
FireSafety c
is disjoint with
DefensiveFireSafety c, StructuralFireSafety c, TechnicalFireSafety c

OtherCertificatec back to ToC or Class ToC

IRI: https://purl.org/fisa#OtherCertificate

Other technical structural certificates that are not fire safety certificates.
has super-classes
TechnicalStructuralCertificate c
is disjoint with
FireSafetyCertificate c

OtherRoomUsagec back to ToC or Class ToC

IRI: https://purl.org/fisa#OtherRoomUsage

has super-classes
SpaceUsage c
has members
OtherRoomUsage ni
is also defined as
named individual

OvernightAccommodationc back to ToC or Class ToC

IRI: https://purl.org/fisa#OvernightAccommodation

has super-classes
UtilizationPurpose c
has members
OvernightAccommodation ni
is also defined as
named individual

PanelInstitutionForLegalExecutiveRegulationsc back to ToC or Class ToC

IRI: https://purl.org/fisa#PanelInstitutionForLegalExecutiveRegulations

Buildings and structures used for detention or rehabilitation as part of the judicial system.
has super-classes
SpecialPurposeCondition c

Parapetc back to ToC or Class ToC

IRI: https://purl.org/fisa#Parapet

A raised area that borders or covers a lower area or opening.
has super-classes
WallParts c
is disjoint with
Apron c, Profile c

Parkingc back to ToC or Class ToC

IRI: https://purl.org/fisa#Parking

has super-classes
UtilizationPurpose c
has members
Parking ni
is also defined as
named individual

ParkingSpacec back to ToC or Class ToC

IRI: https://purl.org/fisa#ParkingSpace

Exception from §2 (7) S3 MBO: Showrooms, salesrooms, workshops and storage rooms for motor vehicles are not parking spaces or garages.
Is defined by
https://purl.org/fisa#MBO
has super-classes
Site c

PenalInstitutionc back to ToC or Class ToC

IRI: https://purl.org/fisa#PenalInstitution

Buildings and structures used for detention or rehabilitation as part of the judicial system.
has super-classes
SpecialPurposeCondition c

PlanningDocumentc back to ToC or Class ToC

IRI: https://purl.org/fisa#PlanningDocument

Planning documents include 2D-documents and/or 3D-models.
has super-classes
AssessmentBasis c
is disjoint with
ClientSpecification c, GeneralInformation c, RuleOfApplication c

PortableConstructionc back to ToC or Class ToC

IRI: https://purl.org/fisa#PortableConstruction

Non-permanent constructions needing authorization for erection, often used for events or specific purposes.
Is defined by
https://purl.org/fisa#M_FIBauR
has super-classes
SpecialPurposeCondition c

PositionAccessibleForFireServicec back to ToC or Class ToC

IRI: https://purl.org/fisa#PositionAccessibleForFireService

Areas, locations, or positions in a building that can be reached by a ladder or similar access device in the event of a fire or emergency by rescue or evacuation teams.
is equivalent to
(Opening c or Parapet c or Window c) and (accessibleForFireServices dp value true)
has super-classes
ComponentType c
is disjoint with
FireResistantEnclosure c, LoadbearingEnclosingComponent c, LoadbearingNonEnclosingComponent c, NonLoadbearingEnclosingComponent c, NonLoadbearingNonEnclosingComponent c

Postsc back to ToC or Class ToC

IRI: https://purl.org/fisa#Posts

Vertical structural element that usually has a supporting or load-bearing function.
has super-classes
AssemblyProduct c
is disjoint with
Fastening c, JointSealing c, Transom c

PrescriptiveCertificatec back to ToC or Class ToC

IRI: https://purl.org/fisa#PrescriptiveCertificate

This approach is based on predetermined building regulations, standards and rules that establish specific fire safety requirements for various building components, materials and situations.
has super-classes
FireSafetyCertificate c
is disjoint with
ProtectiveGoalOrientedCertificate c

Profilec back to ToC or Class ToC

IRI: https://purl.org/fisa#Profile

Wall profile with specific cross-sectional shape.
has super-classes
WallParts c
has sub-classes
ClosedProfile c, OpenProfile c
is disjoint with
Apron c, Parapet c

ProtectiveGoalc back to ToC or Class ToC

IRI: https://purl.org/fisa#ProtectiveGoal

Protection goals based on the MBO: §14 MBO Structural facilites are to be arranged, erected, modified and maintained in such a way that the development of fire and the spread of fire and smoke (fire spread) is prevented and, in the event of fire, the rescue of people and animals and effective extinguishing work are possible.

ProtectiveGoalOrientedCertificatec back to ToC or Class ToC

IRI: https://purl.org/fisa#ProtectiveGoalOrientedCertificate

This approach aims to achieve overall protective goals and to develop individual solutions (for deviations) that achieve these protective goals.
has super-classes
FireSafetyCertificate c
is disjoint with
PrescriptiveCertificate c

RegulatedSpecialPurposeConstructionc back to ToC or Class ToC

IRI: https://purl.org/fisa#RegulatedSpecialPurposeConstruction

Regulated special purpose constructions are special purpose constructions for which there is a special purpose construction regulation. In contrast to unregulated special purpose construction, there are uniform regulations for regulated special puprose construction.
has super-classes
SpecialPurposeConstruction c
is disjoint with
UnregulatedSpecialPurposeConstruction c

RescueConceptc back to ToC or Class ToC

IRI: https://purl.org/fisa#RescueConcept

A rescue concept or deployment strategy describes the approach taken by emergency service personnel in taking their actions in an emergency.
has super-classes
FireSafety c

ResidenceSpacec back to ToC or Class ToC

IRI: https://purl.org/fisa#ResidenceSpace

Residence Rooms are rooms which are intended or suitable for the not only temporary stay of people.
is equivalent to
isPossibleForResidence dp value true
has super-classes
Space c
is disjoint with
Anteroom c, Elevator c, FireFighterLift c, NecessaryCorridor c, NecessaryStairSpace c, SafetyStairSpace c, SecurityGate c, SpaceOfIncreasedFireRisk c, StairSpaceExtension c

Residentialc back to ToC or Class ToC

IRI: https://purl.org/fisa#Residential

has super-classes
UtilizationPurpose c
has members
Residential ni
is also defined as
named individual

Roofc back to ToC or Class ToC

IRI: https://purl.org/fisa#Roof

The top structural covering of a building used to protect it from the elements such as rain, snow, sunlight, and wind.
has super-classes
BuildingElement c
is disjoint with
AssemblyProduct c, Cladding c, Closing c, Installation c, Insulation c, Roofing c, Slab c, Stairs c, StairsParts c, SystemFlooring c, Wall c, WallParts c

Roofingc back to ToC or Class ToC

IRI: https://purl.org/fisa#Roofing

The set of structural elements, materials and devices used to construct and protect the roof of a building.
has super-classes
BuildingElement c
is disjoint with
RoofStructure c, AssemblyProduct c, Cladding c, Closing c, Installation c, Insulation c, Roof c, Slab c, Stairs c, StairsParts c, SystemFlooring c, Wall c, WallParts c

RoofStructurec back to ToC or Class ToC

IRI: https://purl.org/fisa#RoofStructure

Describes the load-bearing components, the supporting structure, of the roof.
has super-classes
Structure c
is disjoint with
Roofing c

RuleOfApplicationc back to ToC or Class ToC

IRI: https://purl.org/fisa#RuleOfApplication

Represents the application rule according to which the requirements are "according to". Example: The partition wall must be at least "fire-retardant", according to §19 (3) MusterBauO.
has super-classes
AssessmentBasis c
has sub-classes
Eurocode c, GeneralPrescription c, Norm c
is disjoint with
ClientSpecification c, GeneralInformation c, PlanningDocument c

SafetyStairSpacec back to ToC or Class ToC

IRI: https://purl.org/fisa#SafetyStairSpace

A safety stair space is a special type of necessary stair space: the necessary staircase running in it represents both the first and the second escape route in one.
has super-classes
Space c
is disjoint with
Anteroom c, Elevator c, FireFighterLift c, NecessaryCorridor c, NecessaryStairSpace c, ResidenceSpace c, SecurityGate c, SpaceOfIncreasedFireRisk c, StairSpaceExtension c

Salesc back to ToC or Class ToC

IRI: https://purl.org/fisa#Sales

has super-classes
UtilizationPurpose c
has members
Sales ni
is also defined as
named individual

SalesPremisesc back to ToC or Class ToC

IRI: https://purl.org/fisa#SalesPremises

§2 (4) 4. MBO 'Retail establishments/sales premises, where the gross floor area of sales spaces and store streets exceeds 800 square meters'
Is defined by
https://purl.org/fisa#MVKVO
has super-classes
SpecialPurposeCondition c
has members
Building07_(SalesPremises) ni

SalesRoomc back to ToC or Class ToC

IRI: https://purl.org/fisa#SalesRoom

has super-classes
SpaceUsage c
has members
SalesRoom ni
is also defined as
named individual

SceneAreac back to ToC or Class ToC

IRI: https://purl.org/fisa#SceneArea

has super-classes
UtilizationPurpose c
has members
SceneArea ni
is also defined as
named individual

Schoolc back to ToC or Class ToC

IRI: https://purl.org/fisa#School

Establishments dedicated to learning - here schools.
Is defined by
https://purl.org/fisa#MSchulbauR
has super-classes
SpecialPurposeCondition c

SecondEscapeRoutec back to ToC or Class ToC

IRI: https://purl.org/fisa#SecondEscapeRoute

The second escape route can either be structural = escape route (another permanently existing fixed structural facility) and serve for self-rescue, or it can be created in case of danger by rescue equipment of the fire department.
has super-classes
EscapeRoute c
is disjoint with
FirstEscapeRoute c

SecurityGatec back to ToC or Class ToC

IRI: https://purl.org/fisa#SecurityGate

Security gate are devices or equipment in buildings that are used to control access to certain sensitive areas and to ensure security-related aspects such as access authorizations, identification and security checks.
has super-classes
Space c
is disjoint with
Anteroom c, Elevator c, FireFighterLift c, NecessaryCorridor c, NecessaryStairSpace c, ResidenceSpace c, SafetyStairSpace c, SpaceOfIncreasedFireRisk c, StairSpaceExtension c

ShelfWarehousec back to ToC or Class ToC

IRI: https://purl.org/fisa#ShelfWarehouse

§2 (4) 18. MBO 'Warehouses with shelf heights exceeding 7.50 meters'
has super-classes
SpecialPurposeCondition c

Sitec back to ToC or Class ToC

IRI: https://w3id.org/bot#Site

A part of the physical world or a virtual world that is inherently both located in this world and having a 3D spatial extent. It is intended to contain or contains one or more buildings.
has super-classes
Zone c
has sub-classes
ExternalDevelopment c, ParkingSpace c
is disjoint with
AtticSpace c, CavitySpace c, FireCompartment c, SmokeCompartment c, StructuralFacility c, Surrounding c, UtilizationUnit c, Space c, Storey c

SiteDevelopmentMeasurec back to ToC or Class ToC

IRI: https://purl.org/fisa#SiteDevelopmentMeasure

The term stands for all structural measures and legal regulations for the proper use of the subsequent building.
has super-classes
FireSafety c
has sub-classes
AccessibilityOfFireFighters c, AreaForFireFighters c, ConstructionalMovingArea c, ExtinguishingWaterAccess c, FireFighterAccessPoint c, FireFighterAccess_Entrance c, InstallationArea c

Slabc back to ToC or Class ToC

IRI: https://purl.org/fisa#Slab

The horizontal surface or structural element that forms the uppermost boundary of a space.
has super-classes
BuildingElement c
has sub-classes
GeneralSlab c, StoreySlab c
is in domain of
isStoreySlab dp
is disjoint with
AssemblyProduct c, Cladding c, Closing c, Installation c, Insulation c, Roof c, Roofing c, Stairs c, StairsParts c, SystemFlooring c, Wall c, WallParts c

SmokeCompartmentc back to ToC or Class ToC

IRI: https://purl.org/fisa#SmokeCompartment

A smoke compartment is a structurally delimited area that prevents the spread of smoke for a certain period of time. Escape and rescue routes should be kept free of smoke and accessible for a certain period of time so that the rescue of persons is possible for a sufficiently long time.
has super-classes
Zone c
is disjoint with
AtticSpace c, CavitySpace c, FireCompartment c, StructuralFacility c, Surrounding c, UtilizationUnit c, Site c, Space c, Storey c

Spacec back to ToC or Class ToC

IRI: https://w3id.org/bot#Space

A part of the physical world or a virtual world whose 3D spatial extent is bounded actually or theoretically, and provides for certain functions within the zone it is contained in. _ In FiSa, the concept is typically used to instantiate actual rooms.
has super-classes
Zone c
has sub-classes
Anteroom c, Elevator c, FireFighterLift c, NecessaryCorridor c, NecessaryStairSpace c, ResidenceSpace c, SafetyStairSpace c, SecurityGate c, SpaceOfIncreasedFireRisk c, StairSpaceExtension c
is in domain of
isPossibleForResidence dp
is in range of
hasSpace op
has members
B03_Space01 ni, B06_Space01 ni, B06_Space02 ni, B06_Space03 ni, B06_Space04 ni, B07_Space01 ni, B07_Space02 ni, B07_Space03 ni, B08_Space ni
is disjoint with
AtticSpace c, CavitySpace c, FireCompartment c, SmokeCompartment c, StructuralFacility c, Surrounding c, UtilizationUnit c, Site c, Storey c

SpaceClosurec back to ToC or Class ToC

IRI: https://purl.org/fisa#SpaceClosure

Ability of a space-enclosing component under fire exposure from one side to prevent the passage of flames and hot gases or the appearance of flames on the non-exposed side for a defined period of time and under standardized fire test conditions. (Construction lexicon)
has super-classes
StructuralFireSafetyMeasures c
has members
TypeFireWall ni, WithoutRequirement ni
is disjoint with
FireBehaviour c

SpaceOfIncreasedFireRiskc back to ToC or Class ToC

IRI: https://purl.org/fisa#SpaceOfIncreasedFireRisk

An increased fire hazard exists in particular if oxidizing, highly flammable or extremely flammable substances are stored, processed or handled in not insignificant quantities according to the hazard characteristics as defined in the Ordinance on Hazardous Substances (GefStoffV).
has super-classes
Space c
is disjoint with
Anteroom c, Elevator c, FireFighterLift c, NecessaryCorridor c, NecessaryStairSpace c, ResidenceSpace c, SafetyStairSpace c, SecurityGate c, StairSpaceExtension c

SpaceUsagec back to ToC or Class ToC

IRI: https://purl.org/fisa#SpaceUsage

Describes both uses of space from regularities and more extensive uses, in the form of everyday uses of space, such as a kitchen.
has super-classes
Usage c
has sub-classes
Administrative c, Bathroom c, Canteen c, Corridor c, Foyer c, Gym c, Kitchen c, LivingRoom c, MeetingRoom c, OfficeRoom c, OtherRoomUsage c, SalesRoom c, StairSpace c, StoreStreet c
is in range of
hasSpaceUsage op
is disjoint with
SpecialPurposeCondition c, StandardConstructionType c, UtilizationPurpose c

SpecialPurposeConditionc back to ToC or Class ToC

IRI: https://purl.org/fisa#SpecialPurposeCondition

Special purpose conditions applicable to buildings classified as "special purpose construction" because of their use, size, special hazards, or other factors.
Is defined by
https://purl.org/fisa#MBO
has super-classes
Usage c
has sub-classes
Accommodation c, AccommodationFacility c, AmusementPark c, ArcadeSpace c, AssemblyBuilding c, Campsite c, DayCareCenter c, Dormitory c, EducationalInstitution c, HighRiseBuilding c, Hospital c, NursingHome c, PanelInstitutionForLegalExecutiveRegulations c, PenalInstitution c, PortableConstruction c, SalesPremises c, School c, ShelfWarehouse c, SpecialPurposeConditionAcc§2_S4_P19 c, SpecialPurposeConditionAcc§2_S4_P2 c, SpecialPurposeConditionAcc§2_S4_P20 c, SpecialPurposeConditionAcc§2_S4_P3 c, SpecialPurposeConditionAcc§2_S4_P5 c, SpecialPurposeConditionAcc§2_S4_P6 c, TavernAndRestaurant c, ThemePark c, University c, WeekendPlace c
is in range of
hasSpecialPurposeCondition op
is disjoint with
SpaceUsage c, StandardConstructionType c, UtilizationPurpose c

SpecialPurposeConditionAcc§2_S4_P19c back to ToC or Class ToC

IRI: https://purl.org/fisa#SpecialPurposeConditionAcc§2_S4_P19

S = Section P = Point Se = Sentence
has super-classes
SpecialPurposeCondition c

SpecialPurposeConditionAcc§2_S4_P2c back to ToC or Class ToC

IRI: https://purl.org/fisa#SpecialPurposeConditionAcc§2_S4_P2

S = Section P = Point Se = Sentence
is equivalent to
hasHeight dp some
has super-classes
SpecialPurposeCondition c

SpecialPurposeConditionAcc§2_S4_P20c back to ToC or Class ToC

IRI: https://purl.org/fisa#SpecialPurposeConditionAcc§2_S4_P20

S = Section P = Point Se = Sentence
has super-classes
SpecialPurposeCondition c

SpecialPurposeConditionAcc§2_S4_P3c back to ToC or Class ToC

IRI: https://purl.org/fisa#SpecialPurposeConditionAcc§2_S4_P3

S = Section P = Point Se = Sentence
has super-classes
SpecialPurposeCondition c

SpecialPurposeConditionAcc§2_S4_P5c back to ToC or Class ToC

IRI: https://purl.org/fisa#SpecialPurposeConditionAcc§2_S4_P5

S = Section P = Point Se = Sentence
has super-classes
SpecialPurposeCondition c

SpecialPurposeConditionAcc§2_S4_P6c back to ToC or Class ToC

IRI: https://purl.org/fisa#SpecialPurposeConditionAcc§2_S4_P6

S = Section P = Point Se = Sentence
has super-classes
SpecialPurposeCondition c

SpecialPurposeConstructionc back to ToC or Class ToC

IRI: https://purl.org/fisa#SpecialPurposeConstruction

Special buildings are facilities and spaces of a special type or use,[...].
Is defined by
https://purl.org/fisa#MBO
has super-classes
Building c
has sub-classes
RegulatedSpecialPurposeConstruction c, UnregulatedSpecialPurposeConstruction c
is disjoint with
StandardConstruction c

SpecialPurposeGuidelinec back to ToC or Class ToC

IRI: https://purl.org/fisa#Sonderbaurichtlinie

This concept unites the special purpose constructions for which there is a guideline.
has super-classes
SpecialPurposePrescription c
has sub-classes
MHHR c, MSchulbauR c, MWR c, M_FIBauR c
is disjoint with
SpecialPurposeRegulation c

SpecialPurposePrescriptionc back to ToC or Class ToC

IRI: https://purl.org/fisa#Sonderbauvorschrift

Special purpose constructions may be subject to special requirements or relief may be permitted if the general safety goal objectives are achieved in an equivalent manner. For so-called regulated special purpose constructions (special purpose constructions for which special purpose regulations exist), these special requirements or relief measures are summarized in corresponding regulations.
has super-classes
GeneralPrescription c
has sub-classes
SpecialPurposeGuideline c, SpecialPurposeRegulation c

SpecialPurposeRegulationc back to ToC or Class ToC

IRI: https://purl.org/fisa#Sonderbauverordnung

This concept unites the special purpose constructions for which there is a regulation.
has super-classes
SpecialPurposePrescription c
has sub-classes
MBeVO c, MEltBauVO c, MVKVO c, MVStättVO c
is disjoint with
SpecialPurposeGuideline c

SpectatorFacilityc back to ToC or Class ToC

IRI: https://purl.org/fisa#SpectatorFacility

has super-classes
UtilizationPurpose c
has members
SpectatorFacility ni
is also defined as
named individual

Sportc back to ToC or Class ToC

IRI: https://purl.org/fisa#Sport

has super-classes
UtilizationPurpose c
has members
Sport ni
is also defined as
named individual

Stairsc back to ToC or Class ToC

IRI: https://purl.org/fisa#Stairs

An immovable structural member permanently attached to the structure for climbing in steps, which are vertical paths in structural systems.
has super-classes
BuildingElement c
is disjoint with
StairsSupportingStructure c, AssemblyProduct c, Cladding c, Closing c, Installation c, Insulation c, Roof c, Roofing c, Slab c, StairsParts c, SystemFlooring c, Wall c, WallParts c

StairSpacec back to ToC or Class ToC

IRI: https://purl.org/fisa#StairSpace

has super-classes
SpaceUsage c
has members
StairSpace ni
is also defined as
named individual

StairSpaceExtensionc back to ToC or Class ToC

IRI: https://purl.org/fisa#StairSpaceExtension

Stair space extensions are spaces that connect stairwells with exits to the outdoors.
has super-classes
Space c
is disjoint with
Anteroom c, Elevator c, FireFighterLift c, NecessaryCorridor c, NecessaryStairSpace c, ResidenceSpace c, SafetyStairSpace c, SecurityGate c, SpaceOfIncreasedFireRisk c

StairsPartsc back to ToC or Class ToC

IRI: https://purl.org/fisa#StairsParts

Describes the parts of a staircase to which fire safety requirements may be applied, e.g. the flight of stairs.
has super-classes
BuildingElement c
is disjoint with
AssemblyProduct c, Cladding c, Closing c, Installation c, Insulation c, Roof c, Roofing c, Slab c, Stairs c, SystemFlooring c, Wall c, WallParts c

StairsSupportingStructurec back to ToC or Class ToC

IRI: https://purl.org/fisa#StairsSupportingStructure

Describes the load-bearing components, the supporting structure, of stairs.
has super-classes
Structure c
is disjoint with
Stairs c

StandardConstructionc back to ToC or Class ToC

IRI: https://purl.org/fisa#StandardConstruction

Buildings are designated as regular or standard construction when there is no feature or condition that leads to classification as special purpose construction.
has super-classes
Building c
is disjoint with
SpecialPurposeConstruction c

StandardConstructionTypec back to ToC or Class ToC

IRI: https://purl.org/fisa#StandardConstructionType

The term "standard construction" refers to buildings that are constructed according to specified standards, guidelines and building regulations. They are buildings that do not meet any special purpose condition of construction.
has super-classes
Usage c
is in range of
hasStandardConstructionType op
is disjoint with
SpaceUsage c, SpecialPurposeCondition c, UtilizationPurpose c

Storagec back to ToC or Class ToC

IRI: https://purl.org/fisa#Storage

has super-classes
UtilizationPurpose c
has members
Storage ni
is also defined as
named individual

StoreStreetc back to ToC or Class ToC

IRI: https://purl.org/fisa#StoreStreet

has super-classes
SpaceUsage c
has members
StoreStreet ni
is also defined as
named individual

Storeyc back to ToC or Class ToC

IRI: https://w3id.org/bot#Storey

A part of the physical world or a virtual world that is inherently both located in this world and having a 3D spatial extent. A bot:Storey is contained in one or more buildings, and is intended to contain one or more spaces that are horizontally connected. Storeys of a building are connected by means of vertical connections such as elevators and stairs. A bot:Storey encompasses both zones above and below ground, for example, a building with 21 floors above ground, one ground floor and 3 basements is equal to the sentence: A building has 25 instances of bot:Storey.
has super-classes
Zone c
has sub-classes
AboveGroundStorey c, Basement c
is in range of
hasStorey op
is disjoint with
AtticSpace c, CavitySpace c, FireCompartment c, SmokeCompartment c, StructuralFacility c, Surrounding c, UtilizationUnit c, Site c, Space c

StoreySlabc back to ToC or Class ToC

IRI: https://purl.org/fisa#StoreySlab

The horizontal surface or structural element located between the floors or stories of a building.
is equivalent to
isStoreySlab dp value true
has super-classes
Slab c
is disjoint with
GeneralSlab c

StructuralFacilityc back to ToC or Class ToC

IRI: https://purl.org/fisa#StructuralFacility

Structural facilities are connected to the ground and made of construction components; a connection to the ground also exists if the structural facility rests on the ground by its own weight or is movable to a limited extent on fixed tracks or if the structural facility is intended by its purpose to be used predominantly in a fixed location. 2Building structures are also 1. fillings and excavations, 2. storage areas, parking areas and exhibition areas, 3. sports and play areas, 4. camping sites, weekend sites and tent sites, 5. recreational and amusement parks, 6. parking places for motor vehicles and parking places for bicycles, 7. scaffolds, 8. auxiliary facilities for static securing of construction conditions. Installations are structural installations and other installations and facilities within the meaning of § 1 Para. 1 Sentence 2.
Is defined by
https://purl.org/fisa#MBO
has super-classes
Zone c
has sub-classes
Building c, Garage c
is disjoint with
AtticSpace c, CavitySpace c, FireCompartment c, SmokeCompartment c, Surrounding c, UtilizationUnit c, Site c, Space c, Storey c

StructuralFireSafetyc back to ToC or Class ToC

IRI: https://purl.org/fisa#StructuralFireSafety

All fire safety measures taken in connection with the construction or alteration of building facilities, e.g.: - the formation of fire compartments, e.g. by fire walls, - the dimensioning or standard-compliant construction of load-bearing and room-enclosing structures, e.g. to protect areas with a high fire risk. Essential criteria are - the fire behavior of building materials - the fire resistance of building components, - the planning and creation of sufficient escape and rescue routes for people and animals.
has super-classes
FireSafety c
has sub-classes
StructuralFireSafetyMeasures c
is disjoint with
DefensiveFireSafety c, OrganizationalFireSafety c, TechnicalFireSafety c

StructuralFireSafetyMeasuresc back to ToC or Class ToC

IRI: https://purl.org/fisa#StructuralFireSafetyMeasures

Unites the essential structural fire safety criteria such as - the fire behavior of building materials - the fire resistance of building components, - the space-enclosing option for components.
has super-classes
StructuralFireSafety c
has sub-classes
FireBehaviour c, FireResistance c, SpaceClosure c

Structurec back to ToC or Class ToC

IRI: https://purl.org/fisa#Structure

Dieses Konzept dient dazu, die Anforderungen die tragenden Teile jedes Bauteils separat noch einmal betrachten zu können. Das ist vor allem Hilfreich, wenn am Ende bei Ausführungen wie dem Layerprinzip der Außenwand in §28 (2) die Wand eingeteilt wird. Da Komponenten ja mit Komponenten verbunden werden und das Objektattribut bot:hatBauteil und bot:hatUnterbauteil nicht eingegrenzt wurden durch die originale BOT-Ontologie, ist ein Verweis und die Aufteilung der Layer sogar innerhalb der gesamten fisa:Komponente möglich, und nicht nur im Konzept bot:Bauteil.
has super-classes
Component c
has sub-classes
RoofStructure c, StairsSupportingStructure c, WallStructure c
is disjoint with
Combustion appliances are fixed installations or equipment used in or on buildings and intended to generate heat by combustion. c, Opening c, SurfaceType c, TechnicalComponent c, BuildingElement c

SurfaceTypec back to ToC or Class ToC

IRI: https://purl.org/fisa#SurfaceType

The outer layer or visible area of components.e
has super-classes
Component c
is disjoint with
Combustion appliances are fixed installations or equipment used in or on buildings and intended to generate heat by combustion. c, Opening c, Structure c, TechnicalComponent c, BuildingElement c

Surroundingc back to ToC or Class ToC

IRI: https://purl.org/fisa#Surrounding

An environment describes a delimited zone that influences an adjacent or remote zone.
has super-classes
Zone c
is disjoint with
AtticSpace c, CavitySpace c, FireCompartment c, SmokeCompartment c, StructuralFacility c, UtilizationUnit c, Site c, Space c, Storey c

SystemFlooringc back to ToC or Class ToC

IRI: https://purl.org/fisa#SystemFlooring

A special design or structural floor assembly used to create levels in a building on which various activities can be performed.
has super-classes
BuildingElement c
is disjoint with
AssemblyProduct c, Cladding c, Closing c, Installation c, Insulation c, Roof c, Roofing c, Slab c, Stairs c, StairsParts c, Wall c, WallParts c

TavernAndRestaurantc back to ToC or Class ToC

IRI: https://purl.org/fisa#TavernAndRestaurant

§2 (4) 8. MBO 'Drinking and dining establishments with more than 40 indoor guest seats or more than 1,000 outdoor guest seats,'[...]
has super-classes
SpecialPurposeCondition c

TechnicalComponentc back to ToC or Class ToC

IRI: https://purl.org/fisa#TechnicalComponent

Combines all technical components relevant to fire safety.
has super-classes
Component c
has sub-classes
FireBrigadeLifts c, FireControl_of_Lifts c, HeatExtractionDevice c, LightningSafetySystem c, ObjectRadioSystem_for_FireBrigade c
is disjoint with
Combustion appliances are fixed installations or equipment used in or on buildings and intended to generate heat by combustion. c, Opening c, Structure c, SurfaceType c, BuildingElement c

TechnicalFireSafetyc back to ToC or Class ToC

IRI: https://purl.org/fisa#TechnicalFireSafety

Technical fire safety is part of preventive fire safety. It includes all technical systems which, among other things: - serve to prevent fires, - detect fires, - have extinguishing functions (sprinklers, fire extinguishers, ...) - support the fire department, e.g. fire department elevators.
has super-classes
FireSafety c
is disjoint with
DefensiveFireSafety c, OrganizationalFireSafety c, StructuralFireSafety c

TechnicalStructuralCertificatec back to ToC or Class ToC

IRI: https://purl.org/fisa#TechnicalStructuralCertificate

The written or calculated evidence prepared by professionals such as engineers, architects, or other qualified persons to confirm compliance with relevant structural engineering requirements and standards for a construction project. These verifications are used to ensure the safety, stability, load-bearing capacity, fire safety, thermal insulation, and other important aspects of a structure.
has super-classes
has sub-classes
FireSafetyCertificate c, OtherCertificate c

Technologyc back to ToC or Class ToC

IRI: https://purl.org/fisa#Technology

has super-classes
UtilizationPurpose c
has members
Technology ni
is also defined as
named individual

ThemeParkc back to ToC or Class ToC

IRI: https://purl.org/fisa#ThemePark

Venue designed for entertainment and leisure.
has super-classes
SpecialPurposeCondition c

Transomc back to ToC or Class ToC

IRI: https://purl.org/fisa#Transom

Horizontal structural element or partition used to prevent the spread of fire, smoke and hot gases within a building or between different areas.
has super-classes
AssemblyProduct c
is disjoint with
Fastening c, JointSealing c, Posts c

Universityc back to ToC or Class ToC

IRI: https://purl.org/fisa#University

Establishments dedicated to learning - here universities.
has super-classes
SpecialPurposeCondition c

UnregulatedSpecialPurposeConstructionc back to ToC or Class ToC

IRI: https://purl.org/fisa#UnregulatedSpecialPurposeConstruction

Unregulated special purpose constructions are special purpose constructions for which there are no special purpose construction regulations. In contrast to regulated special purpose constructions, there are no uniform regulations for unregulated special purpose construction.
has super-classes
SpecialPurposeConstruction c
is disjoint with
RegulatedSpecialPurposeConstruction c

UpperStoreyc back to ToC or Class ToC

IRI: https://purl.org/fisa#UpperStorey

has super-classes
AboveGroundStorey c
has members
B08_UpperStorey ni
is disjoint with
GroundStorey c

Usagec back to ToC or Class ToC

IRI: https://purl.org/fisa#Usage

Describes the use of a structural facility or space, or parts of structural facilities and their spaces, as well as uses that impose utilization units.
has sub-classes
SpaceUsage c, SpecialPurposeCondition c, StandardConstructionType c, UtilizationPurpose c
is in range of
hasUsage op

UtilizationPurposec back to ToC or Class ToC

IRI: https://purl.org/fisa#UtilizationPurpose

has super-classes
Usage c
has sub-classes
Agriculture c, AnimalHusbandry c, Care c, CareForPeople c, ChildCare c, Education c, EmergencyMedicalService c, ExternalDevelopment c, HazardousEnvironment c, Hospitality c, Institution c, Kindergarden c, Lab c, LawEnforcement c, Leisure c, OvernightAccommodation c, Parking c, Residential c, Sales c, SceneArea c, SpectatorFacility c, Sport c, Storage c, Technology c, Work c
is in domain of
isUtilizationPurposeOf op
is in range of
hasUtilizationPurpose op
is disjoint with
SpaceUsage c, SpecialPurposeCondition c, StandardConstructionType c

UtilizationUnitc back to ToC or Class ToC

IRI: https://purl.org/fisa#UtilizationUnit

A utilization unit is a self-contained series of (residential) spaces available for use by one person or a group of persons.
has super-classes
Zone c
is in domain of
hasUser dp
is in range of
hasUtilizationSpace op
has members
B02_UtilizationUnit01 ni, B02_UtilizationUnit02 ni, B03_UtilizationUnit01 ni, B03_UtilizationUnit02 ni, B03_UtilizationUnit03 ni, B04_UtilizationUnit01 ni, B04_UtilizationUnit02 ni, B05_UtilizationUnit01 ni, B1a_UtilizationUnit01 ni
is disjoint with
AtticSpace c, CavitySpace c, FireCompartment c, SmokeCompartment c, StructuralFacility c, Surrounding c, Site c, Space c, Storey c

Wallc back to ToC or Class ToC

IRI: https://purl.org/fisa#Wall

Is a vertical flat component that has a space-forming or space-enclosing function.
has super-classes
BuildingElement c
has sub-classes
CompartmentWall c, DriveShaftWall c, ExternalWall c, FireWall c, WallOfANecessaryCorridor c, WallOfANecessaryStaircase c
is disjoint with
WallStructure c, AssemblyProduct c, Cladding c, Closing c, Installation c, Insulation c, Roof c, Roofing c, Slab c, Stairs c, StairsParts c, SystemFlooring c, WallParts c

WallinsteadOfFireWallc back to ToC or Class ToC

IRI: https://purl.org/fisa#WallinsteadOfFireWall

Under certain conditions, other walls are permitted instead of fire walls, provided they meet the requirements resulting from the state building regulations.
has super-classes
FireWall c
is disjoint with
FireWallAsExternalWall c, InternalFireWall c

WallOfANecessaryCorridorc back to ToC or Class ToC

IRI: https://purl.org/fisa#WallOfANecessaryCorridor

The necessary corridors form the connection to the safe place in case of fire and are required if a building authority escape route from a room or a utilization unit does not lead directly to the outside or to a stairwell. The walls of these necessary corridors have requirements.
has super-classes
Wall c
is disjoint with
CompartmentWall c, DriveShaftWall c, ExternalWall c, FireWall c, WallOfANecessaryStaircase c

WallOfANecessaryStaircasec back to ToC or Class ToC

IRI: https://purl.org/fisa#WallOfANecessaryStaircase

Necessary staircases are part of the system of vertical escape and rescue routes. The walls of these necessary staircases have requirements.
has super-classes
Wall c
is disjoint with
CompartmentWall c, DriveShaftWall c, ExternalWall c, FireWall c, WallOfANecessaryCorridor c

WallPartsc back to ToC or Class ToC

IRI: https://purl.org/fisa#WallParts

Describes the parts or variations of a wall that may be subject to fire safety requirements, e.g. parapet.
has super-classes
BuildingElement c
has sub-classes
Apron c, Parapet c, Profile c
is disjoint with
AssemblyProduct c, Cladding c, Closing c, Installation c, Insulation c, Roof c, Roofing c, Slab c, Stairs c, StairsParts c, SystemFlooring c, Wall c

WallStructurec back to ToC or Class ToC

IRI: https://purl.org/fisa#WallStructure

Describes the load-bearing components, the supporting structure, of a wall.
has super-classes
Structure c
is disjoint with
Wall c

WeekendPlacec back to ToC or Class ToC

IRI: https://purl.org/fisa#WeekendPlace

Outdoor areas equipped for recreational use, often featuring amenities for camping and leisure activities.
has super-classes
SpecialPurposeCondition c

Windowc back to ToC or Class ToC

IRI: https://purl.org/fisa#Window

The closing of an opening in the wall of a building, usually glazed, allowing light, air, and view.
has super-classes
Closing c
is disjoint with
Door c, FireDamper c, Gate c, Glazing c

Workc back to ToC or Class ToC

IRI: https://purl.org/fisa#Work

has super-classes
UtilizationPurpose c
has members
Work ni
is also defined as
named individual

Zonec back to ToC or Class ToC

IRI: https://w3id.org/bot#Zone

has sub-classes
AtticSpace c, CavitySpace c, FireCompartment c, Site c, SmokeCompartment c, Space c, Storey c, StructuralFacility c, Surrounding c, UtilizationUnit c
is in domain of
adjacentZone op, containsZone op, hasBuilding op, hasBuildingClass op, hasCavity op, hasElement op, hasFireCompartment op, hasSpace op, hasStorey op, hasUtilizationSpace op, intersectsZone op, remoteZone op
is in range of
adjacentZone op, containsZone op, intersectsZone op, remoteZone op

Object Properties

adjacentElementop back to ToC or Object Property ToC

IRI: https://w3id.org/bot#adjacentElement

Relation between a zone and its adjacent building components, bounding the zone.
has super-properties
hasElement op

adjacentZoneop back to ToC or Object Property ToC

IRI: https://w3id.org/bot#adjacentZone

Relationship between two zones that share a common interface, but do not intersect.
Is defined by
https://w3id.org/bot#

has characteristics: symmetric

has domain
Zone c
has range
Zone c

asARuleOfApplicationFollowedByop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#asARuleOfApplicationFollowedBy

Relation to buildings and its components needing classification using regulations, guidelines and other directives. The typical range of fisa:asARuleOfApplicationFollowedBy are instances of fisa:StructuralFacility.
has super-properties
isAssessmentBasisOf op
is inverse of
followsRulesOfApplication op

containsElementop back to ToC or Object Property ToC

IRI: https://w3id.org/bot#containsElement

Relation to a building component contained in a zone.
has super-properties
hasElement op
has sub-property chains
containsZone op o containsElement op

containsZoneop back to ToC or Object Property ToC

IRI: https://w3id.org/bot#containsZone

Relationship to the subzones of a major zone. A space zone could for instance be contained in a storey zone which is further contained in a building zone. bot:containsZone is a transitive property. This implies that in the previous example a bot:containsZone relationship holds between the space zone and the building zone.
Is defined by
https://w3id.org/bot#

has characteristics: transitive

has sub-properties
hasAtticSpace op, hasBuildingFacility op, hasCavity op, hasFireCompartment op, hasSmokeCompartment op, hasSpace op, hasStorey op, hasUtilizationSpace op
has domain
Zone c
has range
Zone c

followsRulesOfApplicationop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#followsRulesOfApplication

Relation to regulations, guidelines and other directives needed for classifiying buildings and its components. The typical domains of fisa:followsRuleOfApplication are instances of fisa:StructuralFacility.
has super-properties
hasAssessmentBasis op
is inverse of
asARuleOfApplicationFollowedBy op

hasAccessiblePositionForFireServicesop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasAccessiblePositionForFireServices

Relation to accessible positions for fire services related to a component. The typical domains of fisa:hasAccessiblePossitionForFireServices are instances of fisa:Component.
has super-properties
top object property
is inverse of
isAnAccessiblePositionForFireServicesOf op

hasAssessmentBasisop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasAssessmentBasis

Relationship to the subconcepts of an assessment basis. An assessment basis is a a type of document that helps the engineer to develop the fire safety certificate for building permits.

hasAtticSpaceop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasAtticSpace

Relation to attic spaces contained in a zone. The typical domains of fisa:hasAtticSpace are instances of bot:Storey or fisa:StructuralFacility.
has super-properties
containsZone op

hasBuildingop back to ToC or Object Property ToC

IRI: https://w3id.org/bot#hasBuilding

Relation to buildings contained in a zone. The typical domains of bot:hasBuilding are instances of bot:Site.
has super-properties
hasBuildingFacility op
has domain
Zone c
has range
Building c

hasBuildingClassop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasBuildingClass

Relationship to classifications of buildings. The typical domains of fisa:hasBuildingClass are instances of bot:Building.
has super-properties
hasClassification op
has domain
Zone c
has range
BuildingClass c
is inverse of
isBuildingClassOf op

hasBuildingFacilityop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasBuildingFacility

Relation to structural facilities contained in a zone. The typical domains of fisa:hasBuildingFacility are instances of bot:Site.
has super-properties
containsZone op
has sub-properties
hasBuilding op, hasGarage op

hasBuildingMaterialClassop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasBuildingMaterialClass

Relationship to building material classes of building materials and components. The typical domains of fisa:hasBuildingMaterialClass are instances of fisa:Component.
has super-properties
hasClassification op
has range
BuildingMaterialClass c
is inverse of
isBuildingMaterialClassOf op

hasCavityop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasCavity

Relation to cavities contained in a zone. The typical domains of fisa:hasCavity are instances of bot:Space, bot:Storey or fisa:StructuralFacility.
has super-properties
containsZone op
has domain
Zone c
has range
CavitySpace c

hasClassificationop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasClassification

Relationship to classifications of buildings and their components. The typical domains of fisa:hasClassification are instances of bot:Building or fisa:Component.

has characteristics: transitive

has super-properties
top object property
has sub-properties
hasBuildingClass op, hasBuildingMaterialClass op
is inverse of
isClassificationOf op

hasClientSpecificationop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasClientSpecification

Relation to specifications made by clients needed for classifiying buildings and its components. The typical domains of fisa:hasClientSpecification are instances of fisa:StructuralFacility.
has super-properties
hasAssessmentBasis op
is inverse of
isClientSpecificationOf op

hasComponentTypeop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasComponentType

Links a Component to an Component Type. The intended use of this relationship is not to be stated explicitly, but to be inferred from its sub-properties. It will, for example, allow one to query for all the possible accessible positions for fire fighting services like an instructable position.
has domain
BuildingElement c
has range
ComponentType c
is inverse of
isComponentTypeOf op

hasElementop back to ToC or Object Property ToC

IRI: https://w3id.org/bot#hasElement

Links a Zone to an Component that is either contained in, adjacent to or intersecting with the Zone. The intended use of this relationship is not to be stated explicitly, but to be inferred from its sub-properties. It will, for example, allow one to query for all the doors of a building given that they have an adjacency to spaces of the building. __ In FiSa and its layering system, the range is fisa:Component instead of bot:BuildingElement.
has sub-properties
adjacentElement op, containsElement op, intersectingElement op
has domain
Zone c
has range
Component c
has sub-property chains
containsZone op o hasElement op

hasEscapeRouteop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasEscapeRoute

Links a zone with an escape route. It allows, for example, to query all rooms involved in the escape route and, deriving from this, the adjacent components of these rooms, which in turn receive special requirements.
is inverse of
isEscapeRouteOf op

hasFireBehaviourop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasFireBehaviour

Associates a component with the fire behaviour assigned to it (as-is state).
has super-properties
hasStructuralFireSafetyMeasure op
has range
FireBehaviour c

hasFireCompartmentop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasFireCompartment

Relation to fire compartments contained in a zone. The typical domains of fisa:hasFireCompartment are instances of bot:Storey or fisa:StructuralFacility.
has super-properties
containsZone op
has domain
Zone c
has range
FireCompartment c

hasFireResistanceop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasFireResistance

Associates a component with the fire resistant assigned to it (as-is state).
has super-properties
hasStructuralFireSafetyMeasure op
has range
FireResistance c

hasGarageop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasGarage

Relation to garages contained in a zone. The typical domains of fisa:hasGarage are instances of bot:Site.
has super-properties
hasBuildingFacility op

hasGeneralInformationop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasGeneralInformation

Relation to general information needed for classifiying buildings and its components. The typical domains of fisa:hasGeneralInformation are instances of fisa:StructuralFacility.

has characteristics: transitive

has super-properties
hasAssessmentBasis op
is inverse of
isGeneralInformationOf op

hasPartop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasPart

Links a Concept to another concept that is in close relationship with it. It will, for example, allow one to query for all the necessary parts of a rescue concepts.
is inverse of
isPartOf op

hasPlanningDocumentop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasPlanningDocument

Relation to floor plans and other planning documents for classifiying buildings and its components. The typical domains of fisa:hasPlanningDocument are instances of fisa:StructuralFacility.
has super-properties
hasAssessmentBasis op
is inverse of
isPlanningDocumentOf op

hasProtectiveGoalop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasProtectiveGoal

Links a structural facility to the protective goals it needs to comply with/fulfill.
has super-properties
top object property

hasRequirementop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasRequirement

Connects a component to the minimum requirements it must meet.

hasRequirementOfFireBehaviourop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasRequirementOfFireBehaviour

Connects a component to the minimum requirements of fire behaviour it must meet.
has super-properties
hasRequirement op

hasRequirementOfFireResistanceop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasRequirementOfFireResistance

Connects a component to the minimum requirements of fire resistance it must meet.
has super-properties
hasRequirement op
has range
FireResistance c

hasRequirementOfSpaceClosureop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasRequirementOfSpaceClosure

Connects a component to the minimum requirements of space closure it must meet.
has super-properties
hasRequirement op

hasRescueConceptop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasRescueConcept

Relationship of a rescue concept with respect to a structural facility. The typical domains of fisa:hasRescueConcept are instances of fisa:StructuralFacility.
is inverse of
isRescueConceptOf op

hasSmokeCompartmentop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasSmokeCompartment

Relation to smoke compartments contained in a zone. The typical domains of fisa:hasSmokeCompartment are instances of bot:Storey or fisa:StructuralFacility.
has super-properties
containsZone op

hasSpaceop back to ToC or Object Property ToC

IRI: https://w3id.org/bot#hasSpace

Relation to spaces contained in a zone. The typical domains of bot:hasSpace are instances of bot:Storey or bot:Building.
has super-properties
containsZone op
has sub-properties
hasStairSpaceExit op
has domain
Zone c
has range
Space c

hasSpaceClosureop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasSpaceClosure

Associates a component with the space closure assigned to it (as-is state).

hasSpaceUsageop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasSpaceUsage

Relation to space uses associated with a zone. The typical domains of fisa:hasSpaceUsage are instances of bot:Space.

has characteristics: transitive

has super-properties
hasUsage op
has range
SpaceUsage c
is inverse of
isSpaceUsageOf op

hasSpecialPurposeConditionop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasSpecialPurposeCondition

Relation to special purpose conditions associated with a zone. The typical domains of fisa:hasSpecialPurposeCondition are instances of fisa:StructuralFacility.
has super-properties
hasUsage op
has range
SpecialPurposeCondition c
is inverse of
isSpecialPurposeConditionOf op

hasStairSpaceExitop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasStairSpaceExit

Relation to the kinds of exits a stair space can have, being contained in a zone. The typical domains and ranges of bot:hasStairSpaceExit are limited to instances of fisa:NecessaryStairSpace or fisa:SafetyStairSpace as domains and fisa:StairSpaceExtension or bot:Site as range.
has super-properties
hasSpace op
has domain
NecessaryStairSpace c or SafetyStairSpace c
has range
StairSpaceExtension c or Site c

hasStandardConstructionTypeop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasStandardConstructionType

Relation to standard construction types associated with a zone. The typical domains of fisa:hasStandardConstructionType are instances of fisa:StructuralFacility.
has super-properties
hasUsage op
has range
StandardConstructionType c
is inverse of
isStandardConstructionTypeOf op

hasStoreyop back to ToC or Object Property ToC

IRI: https://w3id.org/bot#hasStorey

Relation to storeys contained in a zone. The typical domains of bot:hasStorey are instances of bot:Building.
has super-properties
containsZone op
has domain
Zone c
has range
Storey c

hasStructuralFireSafetyMeasureop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasStructuralFireSafetyMeasure

Associates a component with the measures assigned to it (actual state).
has super-properties
top object property
has sub-properties
hasFireBehaviour op, hasFireResistance op, hasSpaceClosure op

hasSub-Elementop back to ToC or Object Property ToC

IRI: https://w3id.org/bot#hasSubElement

Relation between several building components, either one element hosting another (e.g. a wall hosts a window) or a subcomposition of a building element into smaller parts (e.g. an air handling unit has as a part a fan).
has domain
Component c
has range
Component c
is inverse of
isSub-ElementOf op

hasUsageop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasUsage

Relation to usages related to a zone. The typical domains of fisa:hasUsage are instances of bot:Zone.
has super-properties
top object property
has sub-properties
hasSpaceUsage op, hasSpecialPurposeCondition op, hasStandardConstructionType op, hasUtilizationPurpose op
has range
Usage c
is inverse of
isUsageOf op

hasUtilizationPurposeop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasUtilizationPurpose

Relation to usage purposes associated with a zone. The typical domains of fisa:hasUsagePurpose are instances of bot:Zone.
has super-properties
hasUsage op
has range
UtilizationPurpose c
is inverse of
isUtilizationPurposeOf op

hasUtilizationSpaceop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#hasUtilizationSpace

Relation to utilization spaces contained in a zone. The typical domains of fisa:hasUtilizationSpace are instances of bot:Storey or fisa:StructuralFacility.
has super-properties
containsZone op
has domain
Zone c
has range
UtilizationUnit c
is inverse of
isUtilizationSpaceOf op

interfaceOfop back to ToC or Object Property ToC

IRI: https://w3id.org/bot#interfaceOf

Relationship between an interface and another thing (building zone, component or owl:Thing)
has domain
Interface c

intersectingElementop back to ToC or Object Property ToC

IRI: https://w3id.org/bot#intersectingElement

Relation between a Zone and a building component that intersects it.
has super-properties
hasElement op

intersectsZoneop back to ToC or Object Property ToC

IRI: https://w3id.org/bot#intersectsZone

Relationship between two zones whose 3D extent intersect. For example, a stairwell intersects different storeys.

has characteristics: symmetric

has domain
Zone c
has range
Zone c

isAnAccessiblePositionForFireServicesOfop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isAnAccessiblePositionForFireServicesOf

Relation of a component to accessible positions for fire services related . The typical range of fisa:ifAccessiblePossitionForFireServicesOf are instances of fisa:Component.
has super-properties
top object property
is inverse of
hasAccessiblePositionForFireServices op

isAssessmentBasisOfop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isAssessmentBasisOf

Relationship to the range that subconcepts of an assessment basis relate to. An assessment basis is a a type of document that helps the engineer to develop the fire safety certificate for building permits.The typical range of fisa:isAssessmentBasisOf are instances of fisa:StructuralFacility.

isBasedOnop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isBasedOn

Relation between two concepts where one concept can only be described if the other concept is present and described.

has characteristics: transitive

has super-properties
top object property
is inverse of
isBasisOf op

isBasisOfop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isBasisOf

Relation between two concepts where the other concept can only be described if this concept is present and described.

has characteristics: transitive

has super-properties
top object property
is inverse of
isBasedOn op

isBuildingClassOfop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isBuildingClassOf

Relationship to buildings and their building classifications. The typical range of fisa:isBuildingClassOf are instances of bot:Building.
has super-properties
isClassificationOf op
is inverse of
hasBuildingClass op

isBuildingMaterialClassOfop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isBuildingMaterialClassOf

Relationship to components and their classifications. The typical range of fisa:isBuildingMaterialClassOf are instances of fisa:Component.
has super-properties
isClassificationOf op
is inverse of
hasBuildingMaterialClass op

isClassificationOfop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isClassificationOf

Relationship to buildings and their components and their classifications. The typical range of fisa:isClassificationOf are instances of bot:Building or fisa:Component.
has super-properties
top object property
has sub-properties
isBuildingClassOf op, isBuildingMaterialClassOf op
has domain
Classification c
is inverse of
hasClassification op

isClientSpecificationOfop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isClientSpecificationOf

Relation to buildings and its components influenced by specifications of clients. The typical range of fisa:isClientSpecificationOf are instances of fisa:StructuralFacility.
has super-properties
isAssessmentBasisOf op
is inverse of
hasClientSpecification op

isComponentTypeOfop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isComponentTypeOf

Links a Component Type to an Component.
has super-properties
top object property
is inverse of
hasComponentType op

isEscapeRouteOfop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isEscapeRouteOf

Links an escape route to a zone.
is inverse of
hasEscapeRoute op

isGeneralInformationOfop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isGeneralInformationOf

Relation to buildings and its components needing classification using general information. The typical range of fisa:isGeneralInformationof are instances of fisa:StructuralFacility.
has super-properties
isAssessmentBasisOf op
is inverse of
hasGeneralInformation op

isLessFireResistantThanop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isLessFireResistantThan

Relation of descending fire resistance of components. Used to create a kind of list from instances of fire resistance.
is inverse of
isMoreFireResistantThan op

isLessFlammableThanop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isLessFlammableThan

Relation of descending fire behavior of components. Used to create a kind of list from instances of fire behavior.
is inverse of
isMoreFlammableThan op

isMoreFireResistantThanop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isMoreFireResistantThan

Relation of ascending fire resistance of components. Used to create a kind of list from instances of fire resistance.

has characteristics: transitive

has domain
FireResistance c
has range
FireResistance c
is inverse of
isLessFireResistantThan op

isMoreFlammableThanop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isMoreFlammableThan

Relation of ascending fire behavior of components. Used to create a kind of list from instances of fire behavior.

has characteristics: transitive

has domain
FireBehaviour c
has range
FireBehaviour c
is inverse of
isLessFlammableThan op

isNeededByop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isNeededBy

Relation of required concepts to describe other concepts.

has characteristics: transitive

has super-properties
top object property
is inverse of
needs op

isPartOfop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isPartOf

Links a Concept to another concept that is in close relationship with it.
is inverse of
hasPart op

isPermittedWithop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isPermittedWith

Connects a component to the requirements it is permitted to have under certain circumstances/actual states.

isPermittedWithFireBehaviourop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isPermittedWithFireBehaviour

Connects a component to the requirements of fire behaviour it is permitted to have under certain circumstances/actual states.
has super-properties
isPermittedWith op
has range
FireBehaviour c

isPermittedWithFireResistanceop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isPermittedWithFireResistance

Connects a component to the requirements of fire resistance it is permitted to have under certain circumstances/actual states.
has super-properties
isPermittedWith op
has range
FireResistance c

isPermittedWithSpaceClosureop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isPermittedWithSpaceClosure

Connects a component to the requirements of space closure it is permitted to have under certain circumstances/actual states.
has super-properties
isPermittedWith op

isPlanningDocumentOfop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isPlanningDocumentOf

Relation to buildings and its components and its related planning documents. The typical range of fisa:isPlanningDocumentOf are instances of fisa:StructuralFacility.
has super-properties
isAssessmentBasisOf op
is inverse of
hasPlanningDocument op

isRescueConceptOfop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isRescueConceptOf

Relation of a structural facility with respect to the rescue concept . The typical range of fisa:isRescueConceptOf are instances of fisa:StructuralFacility.
is inverse of
hasRescueConcept op

isSpaceUsageOfop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isSpaceUsageOf

Relation of a zone associated with space uses. The typical range of fisa:isSpaceUsageOf are instances of bot:Space.
has super-properties
isUsageOf op
is inverse of
hasSpaceUsage op

isSpecialPurposeConditionOfop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isSpecialPurposeConditionOf

Relation of a zone associated with special purpose conditions. The typical range of fisa:isSpecialPurposeConditionOf are instances of fisa:StructuralFacility.
has super-properties
isUsageOf op
is inverse of
hasSpecialPurposeCondition op

isStandardConstructionTypeOfop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isStandardConstructionTypeOf

Relation of a zone associated with standard construction types. The typical range of fisa:isStandardConstructionTypeOf are instances of fisa:StructuralFacility.
has super-properties
isUsageOf op
is inverse of
hasStandardConstructionType op

isSub-ElementOfop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isSubElementOf

Relation between several building elements, either one element hosting another (e.g. window being hosted by a wall) or a subcomposition of a building element into bigger parts (e.g. a fan has a sub part that is an air handling unit).
has domain
Component c
has range
Component c
is inverse of
hasSub-Element op

isUsageOfop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isUsageOf

Relation of a zone to a usage. The typical range of fisa:isUsageOf are instances of bot:Zone.
has super-properties
top object property
has sub-properties
isSpaceUsageOf op, isSpecialPurposeConditionOf op, isStandardConstructionTypeOf op, isUtilizationPurposeOf op
is inverse of
hasUsage op

isUtilizationPurposeOfop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isUtilizationPurposeOf

Relation of a zone associated with usage purposese. The typical range of fisa:ifUsagePurposeOf are instances of bot:Zone.
has super-properties
isUsageOf op
has domain
UtilizationPurpose c
is inverse of
hasUtilizationPurpose op

isUtilizationSpaceOfop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#isUtilizationSpaceOf

Relation to a zone, which contains utilization spaces. The typical range of fisa:isUtilizationSpaceOf are instances of bot:Storey or fisa:StructuralFacility.
has super-properties
top object property
is inverse of
hasUtilizationSpace op

needsop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#needs

Relation of required concepts to describe other concepts.

has characteristics: transitive

has super-properties
top object property
is inverse of
isNeededBy op

remoteZoneop back to ToC or Object Property ToC

IRI: https://purl.org/fisa#remoteZone

Relationship between two zones that share no common interface and are remote to one another, but influence each other.
has domain
Zone c
has range
Zone c

Data Properties

accessibleForFireServicesdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#accessibleForFireServices

Describes whether a component is instructable and therefore accessible for fire services.
has super-properties
top data property
has domain
Door c or Opening c or Parapet c or Window c
has range
boolean

hasAgedp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasAge

Describes whether a facility deals with elderly persons. (can be replaced by other existing ontology concepts).
has super-properties
top data property
has range
integer

hasAverageHeightdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasAverageHeight

Height in the sense of sentence 1 is the dimension of the upper floor edge of the highest floor in which a residential space is possible, above the ground surface on average.
Is defined by
https://purl.org/fisa#MBO
has super-properties
top data property
has range
double

hasCombinedGrossFloorAreadp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasCombinedGrossFloorArea

The floor areas of the utilization spaces within the meaning of this Act shall be the gross floor areas; areas in basements shall not be taken into account when calculating the gross floor areas pursuant to sentence 1.
Is defined by
https://purl.org/fisa#MBO
has super-properties
top data property
has range
double

hasDescriptiondp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasDescription

Used to further describe concepts.
has super-properties
top data property
has range
string

hasDisabilitydp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasDisability

Describes whether a person is exposed to a disability.
has super-properties
top data property
has range
boolean

hasEscapeRouteWidthdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasEscapeRouteWidth

Describes the width of the escape routes.
has domain
Door c or Opening c or Stairs c or Space c
has range
double

hasGFASalesSpacesdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasGFASalesSpaces

Used to define the combined griss floor area of sales premises and store street for the special purpose construction as sales premises, §2 (4) 4. MBO.
has super-properties
top data property
has range
double

hasHeightdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasHeight

Describes the overall height of a building structure.
has range
double

hasIntensiveCareNeeddp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasIntensiveCareNeed

Describes whether there is a need for intensive care.
has range
boolean

hasNeedForCaredp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasNeedForCare

Describes whether there is a need for general care.
has super-properties
top data property
has range
boolean

hasNumberOfBedsdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasNumberOfBeds

Describes the number of beds, associated with accommodations.
has super-properties
top data property
has range
integer

hasNumberOfHostPlacesdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasNumberOfHostPlaces

Describes the number of host places, associated with accommodations.
has super-properties
top data property
has range
integer

hasNumberOfPeopledp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasNumberOfPeople

Describes the number of people, associated with gatherings/meetings.
has super-properties
top data property
has range
integer

hasNumberOfVisitorsdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasNumberOfVisitors

Describes the number of visitors, associated with gatherings/meetings.
has super-properties
top data property
has range
integer

hasOutdoorHostPlacesdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasOutdoorHostPlaces

Describes the number of outdoor host places, associated with hospitalities/restaurants.
has super-properties
top data property
has range
boolean

hasSharedEscapeRoutedp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasSharedEscapeRoute

Describes whether concepts share the same escape route.
has super-properties
top data property
has range
boolean

hasStairSpaceLocationdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasStairSpaceLocation

Describes the location of stair spaces, located within a structural facility.
has domain
NecessaryStairSpace c or SafetyStairSpace c or StairSpaceExtension c
has range
{ "außenliegend" , "innenliegend" }

hasStiffeningdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasStiffening

Describes whether a component has stiffening.
has super-properties
top data property
has range
boolean

hasStorageItemHeightdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasStorageItemHeight

Describes the storage item height according to §2 (4) 18. MBO
has range
double

hasTotalAmountOfUtilizationUnitsdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasTotalAmountOfUtilizationUnits

Describes the total amount of utilization spaces.
has super-properties
top data property
has range
int

hasTotalNumberOfStoreysdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasTotalNumberOfStoreys

Describes the total amount of storeys.
has super-properties
top data property
has range
int

hasUnitdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasUnit

Describes what unit values have. _ Note: In FiSa 1.0.0, these are implied.
has range
string

hasUpperEndingAtdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasUpperEndingAt

has upper ending at = is led up to e.g. raw ceiling
has super-properties
top data property
has range
string

hasUsefulWidthdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasUsefulWidth

Describes wheter the width of zones and/or components are useful (in terms of escaping).
has super-properties
top data property
has domain
Door c or Opening c or Stairs c or Space c
has range
boolean

hasUserdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#hasUser

Describes the names of utilization space users.
has super-properties
top data property
has domain
UtilizationUnit c
has range
string

isBarrierFreedp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#isBarrierFree

Structural facilities are barrier-free if they are accessible and usable for people with disabilities in the generally usual manner, without particular difficulty and generally without outside assistance.
has range
boolean

isClosedProfiledp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#isClosedProfile

Describes whether the component is a closed profile. It can be used, for instance, to define parts of non-load-bearing external walls according to §28 MBO.
has super-properties
isProfile dp
has range
boolean

isExternaldp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#isExternal

Describes wheter a component is external.
has range
boolean

isFreestandingdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#isFreestanding

Describes whether a structural facility is freestanding /detached.
has super-properties
top data property
has range
boolean

isFullStoreydp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#isFullStorey

Describes whether this is a full storey.
has super-properties
top data property
has range
boolean

isHighestStoreyWithPossibleResidenceSpacedp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#isHighestStoreyWithPossibleResidenceSpace

Describes wheter it is the highest storey with a possible residence space.
has super-properties
top data property
has range
boolean

isLoadBearingdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#isLoadBearing

Describes whether a component is load-bearing.
has super-properties
top data property
has range
boolean

isNecessarydp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#isNecessary

Describes whether a component or zone is necessary.
has super-properties
top data property
has range
boolean

isOpenedProfiledp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#isOpenedProfile

Describes whether the component is an open profile. It can be used, for instance, to define parts of non-load-bearing external walls according to §28 MBO.
has super-properties
isProfile dp
has range
boolean

isPossibleForResidencedp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#isPossibleForResidence

Describes whether a zone is capable of residence.
has domain
Space c
has range
boolean

isProfiledp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#isProfile

Describes whether the component is a profile. It can be used, for instance, to define parts of non-load-bearing external walls according to §28 MBO.
has super-properties
top data property
has sub-properties
isClosedProfile dp, isOpenedProfile dp
has range
boolean

isSelfClosingdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#isSelfClosing

Describes whether a component is self closing.
has super-properties
top data property
has range
boolean

isSmokeResistantdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#isSmokeResistant

Describes wheter a component or zone is smoke resistant.
has range
boolean

isSpaceEnclosingdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#isSpaceEnclosing

Describes wheter a component or zome is space closed or has a requirement for a room closure.
has super-properties
top data property
has range
boolean

isStoreySlabdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#isStoreySlab

Describes wheter a slab serves as a storey slab.
has domain
Slab c
has range
boolean

isTightClosingdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#isTightClosing

Describes wheter a component is tight closing.
has super-properties
top data property
has range
boolean

isTypedp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#isType

Can be used to represent other concepts/components not yet assigned.
has range
string

isUndergroundBuildingdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#isUndergroundBuilding

Describes whether a building is defined an underground building.
has range
boolean

isUsabledp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#isUsable

Describes wheter a zone or component is usable according to MBO. To define, for instance, the roof space and related concepts according to MBO.
has domain
AtticSpace c
has range
boolean

largestUtilizationSpacedp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#largestUtilizationSpace

Describes the amount of square meters of gross floor area of the largest utilizaton space.
has range
double

outdoorsdp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#outdoors

Describes whether something is in the outdoors.
has range
boolean

under400_metadp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#under400_meta

Used as an example to temporarily store values calculated from queries. So they can be used for the next query or for inference. -> therefore meta data. Example: In [under400_meta] can be stored if all utilization units of a building occupy <= 400m2 gross floor area. From this meta attribute, e.g. building classes can then be directly inferred. ---- Tip: By using the data type attribute [largestUtilizationSpace] you can achieve similar results.
has range
boolean

usesGrossFloorAreadp back to ToC or Data Property ToC

IRI: https://purl.org/fisa#usesGrossFloorArea

Describes the gross floor area of individual utilization spaces or rooms. For an addition of the gross floor area for the determination of building classes, a combined sum value is stored in [fisa:hasCombinedGrossFloorArea].
has range
double

Annotation Properties

accordingToap back to ToC or Annotation Property ToC

IRI: https://purl.org/fisa#gemäß

has range
anwendungsregel

alt labelap back to ToC or Annotation Property ToC

IRI: http://www.w3.org/2004/02/skos/core#altLabel

applicationAreaap back to ToC or Annotation Property ToC

IRI: https://purl.org/fisa#anwendungsbereich

To explain the application area of regulations, guidelines, prescriptions, etc. Mostly it refers to the first section of a paragaph of the respective legal basis.

contributorap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/contributor

createdap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/created

creatorap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/creator

descriptionap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/description

is rule enabledap back to ToC or Annotation Property ToC

IRI: http://swrl.stanford.edu/ontologies/3.3/swrla.owl#isRuleEnabled

licenseap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/license

preferred namespace prefixap back to ToC or Annotation Property ToC

IRI: http://purl.org/vocab/vann/preferredNamespacePrefix

preferred namespace uriap back to ToC or Annotation Property ToC

IRI: http://purl.org/vocab/vann/preferredNamespaceUri

subjectap back to ToC or Annotation Property ToC

IRI: https://purl.org/fisa#thematik

Is used or can be used to unite concepts and attributes under one subject matter. Like e.g. everything that influences each other rescue concept-wise can be marked this way. Queries can be also supported. ___ Remark: This is mainly due to the conception of the ontology that knowledge is mostly inferred by reasoners and less class restrictions are used. -> Disjoint classes play a major role using complex rule sets; reasoners can be supported a bit this way. A fine mix of both makes fisa a usable scheme for compliance checks.

titleap back to ToC or Annotation Property ToC

IRI: http://purl.org/dc/terms/title

toDefineap back to ToC or Annotation Property ToC

IRI: https://purl.org/fisa#zurDefinitionVon

unter400 metaap back to ToC or Annotation Property ToC

IRI: https://purl.org/fisa#unter400_meta

Named Individuals

Administrativeni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Administrative

belongs to
Administrative c
is also defined as
class

Agricultureni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Agriculture

belongs to
Agriculture c
is also defined as
class

AnimalHusbandryni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#AnimalHusbandry

belongs to
AnimalHusbandry c
is also defined as
class

B02_UtilizationUnit01ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Geb02_NE01

belongs to
UtilizationUnit c
has facts
usesGrossFloorArea dp "150.0"^^double

B02_UtilizationUnit02ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Geb02_NE02

belongs to
UtilizationUnit c
has facts
usesGrossFloorArea dp "100.0"^^double

B03_Space01ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Raum01

belongs to
Space c
has facts
hasSpaceUsage op OfficeRoom
hasNumberOfPeople dp "120"^^integer

B03_UtilizationUnit01ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Geb03_NE01

belongs to
UtilizationUnit c
has facts
usesGrossFloorArea dp "200.0"^^double

B03_UtilizationUnit02ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Geb03_NE02

belongs to
UtilizationUnit c
has facts
usesGrossFloorArea dp "100.0"^^double

B03_UtilizationUnit03ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Geb03_NE03

belongs to
UtilizationUnit c
has facts
usesGrossFloorArea dp "100.0"^^double

B04_UtilizationUnit01ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Geb04_NE01

belongs to
UtilizationUnit c
has facts
usesGrossFloorArea dp "380.0"^^double

B04_UtilizationUnit02ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Geb04_NE02

belongs to
UtilizationUnit c
has facts
usesGrossFloorArea dp "200.0"^^double

B05_UtilizationUnit01ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Geb05_NE01

belongs to
UtilizationUnit c
has facts
usesGrossFloorArea dp "500.0"^^double

B06_FirstEscapeRouteni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#ErsterRettungswegGeb06

belongs to
FirstEscapeRoute c

B06_Space01ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Geb06_Raum01

belongs to
Space c
has facts
hasUsage op OfficeRoom
usesGrossFloorArea dp "450.0"^^double

B06_Space02ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Geb06_Raum02

belongs to
Space c
has facts
hasUsage op MeetingRoom
hasNumberOfVisitors dp "100"^^integer

B06_Space03ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Geb06_Raum03

belongs to
Space c
has facts
hasEscapeRoute op B06_FirstEscapeRoute
hasUsage op MeetingRoom
hasNumberOfVisitors dp "50"^^integer

B06_Space04ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Geb06_Raum04

belongs to
Space c
has facts
hasEscapeRoute op B06_FirstEscapeRoute
hasUsage op MeetingRoom
hasNumberOfVisitors dp "125"^^integer

B07_GroundStoreyni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#10_EG

belongs to
GroundStorey c
has facts
hasSpace op B07_Space01
hasSpace op B07_Space02
hasSpace op B07_Space03

B07_Space01ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#10_Raum01

belongs to
Space c
has facts
hasUsage op SalesRoom
usesGrossFloorArea dp "1900.0"^^double

B07_Space02ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#10_Raum02

belongs to
Space c
has facts
hasUsage op StoreStreet
usesGrossFloorArea dp "300.0"^^double

B07_Space03ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#10_Raum03

belongs to
Space c
has facts
hasUsage op OfficeRoom
usesGrossFloorArea dp "150.0"^^double

B08_ClosedProfile01ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#11_GProfil

belongs to
ClosedProfile c
has facts
hasFireBehaviour op non-flammable
hasFireResistance op fire-retardent
containsElement op B08_Insulation01
containsElement op B08_Insulation02

B08_ClosedProfile02ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Geb08_GeschlossenesProfil02

belongs to
ClosedProfile c
has facts
hasFireBehaviour op non-flammable
hasFireResistance op fire-retardent
containsElement op B08_Insulation02

B08_ExternalWall01ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#11_Außenwand01

belongs to
ExternalWall c
has facts
hasFireResistance op fire-retardent
hasSub-Element op B08_Fastening
hasSub-Element op B08_Insulation01
hasSub-Element op B08_Insulation02
hasSub-Element op B08_ClosedProfile01
isLoadBearing dp "false"^^boolean
isSpaceEnclosing dp "true"^^boolean

B08_Fasteningni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#11_Befestigung

belongs to
Fastening c
has facts
hasFireResistance op fire-retardent
isLoadBearing dp "false"^^boolean

B08_Insulation01ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#11_Dämmstoff

belongs to
Insulation c
has facts
hasFireBehaviour op flammable

B08_Insulation02ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#11_Dämmstoff02

belongs to
Insulation c
has facts
hasFireBehaviour op normal-flammable

B08_Spaceni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#11_Raum

belongs to
Space c
has facts
hasElement op B08_ExternalWall01

B08_UpperStoreyni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#11_OG

belongs to
UpperStorey c
has facts
hasSpace op B08_Space

B1a_UtilizationUnit01ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Geb01_NE01

belongs to
UtilizationUnit c
has facts
usesGrossFloorArea dp "350.0"^^double

Bathroomni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Bathroom

belongs to
Bathroom c
is also defined as
class

Building05ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Gebäude05

belongs to
Building c
has facts
hasUtilizationSpace op B05_UtilizationUnit01
hasAverageHeight dp "25.0"^^double
hasCombinedGrossFloorArea dp "500.0"^^double
hasTotalAmountOfUtilizationUnits dp "1"^^integer
under400_meta dp "false"^^boolean

Building06_(Assembly)ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Gebäude06

belongs to
Building c
has facts
hasEscapeRoute op B06_FirstEscapeRoute
hasSpace op B06_Space01
hasSpace op B06_Space02
hasSpace op B06_Space03
hasSpace op B06_Space04

Building07_(SalesPremises)ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Gebäude10

belongs to
SalesPremises c
Building c
has facts
hasStorey op B07_GroundStorey
hasGFASalesSpaces dp "2200.0"^^double

Building08_(LayerSystem)ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Gebäude11

belongs to
Building c
has facts
hasBuildingClass op BuildingClass4
hasStorey op B08_UpperStorey

Building1ani back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Gebäude1a

belongs to
Building c
has facts
hasUtilizationSpace op B1a_UtilizationUnit01
hasAverageHeight dp "6.0"^^double
hasCombinedGrossFloorArea dp "350.0"^^double
hasTotalAmountOfUtilizationUnits dp "1"^^integer
isFreestanding dp "true"^^boolean
under400_meta dp "true"^^boolean

Building1bni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Gebäude1b

belongs to
Building c
has facts
hasUsage op Agriculture
isFreestanding dp "true"^^boolean

BuildingClass1ani back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#BuildingClass1a

belongs to
BuildingClass1a c
is disjoint with
BuildingClass1b
is also defined as
class

BuildingClass1bni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#BuildingClass1b

belongs to
BuildingClass1b c
is disjoint with
BuildingClass1a
is also defined as
class

BuildingClass2ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#BuildingClass2

belongs to
BuildingClass2 c
is disjoint with
BuildingClass1, BuildingClass3, BuildingClass4, BuildingClass5
is also defined as
class

BuildingClass3ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#BuildingClass3

belongs to
BuildingClass3 c
is disjoint with
BuildingClass1, BuildingClass2, BuildingClass4, BuildingClass5
is also defined as
class

BuildingClass4ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#BuildingClass4

belongs to
BuildingClass4 c
is disjoint with
BuildingClass1, BuildingClass2, BuildingClass3, BuildingClass5
is also defined as
class

BuildingClass5ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#BuildingClass5

belongs to
BuildingClass5 c
is disjoint with
BuildingClass1, BuildingClass2, BuildingClass3, BuildingClass4
has facts
hasDescription dp "Dies ist die Beschreibung für Klasse 5."
is also defined as
class

Canteenni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Canteen

belongs to
Canteen c
is also defined as
class

Careni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Care

belongs to
Care c
is also defined as
class

CareForPeopleni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#CareForPeople

belongs to
CareForPeople c
is also defined as
class

ChildCareni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#ChildCare

belongs to
ChildCare c
is also defined as
class

Corridorni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Corridor

belongs to
Corridor c
is also defined as
class

Educationni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Education

belongs to
Education c
is also defined as
class

EmergencyMedicalServiceni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#EmergencyMedicalService

belongs to
EmergencyMedicalService c
is also defined as
class

ExternalDevelopmentni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#ExternalDevelopment

belongs to
ExternalDevelopment c
is also defined as
class

fire-resistantni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#feuerbeständig

belongs to
FireResistance c
has facts
isMoreFireResistantThan op highly-fire-retardent

fire-retardentni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#feuerhemmend

belongs to
FireResistance c

flammableni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#brennbar

belongs to
FireBehaviour c
has facts
isMoreFlammableThan op highly-flammable

Foyerni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Foyer

belongs to
Foyer c
is also defined as
class

geb03 dachraumni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Geb03_Dachraum

belongs to
AtticSpace c

Gymni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Gym

belongs to
Gym c
is also defined as
class

HazardousEnvironmentni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#HazardousEnvironment

belongs to
HazardousEnvironment c
is also defined as
class

highly-fire-resistantni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#hochfeuerbeständig

belongs to
FireResistance c
has facts
isMoreFireResistantThan op fire-resistant

highly-fire-retardentni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#hochfeuerhemmend

belongs to
FireResistance c
has facts
isMoreFireResistantThan op fire-retardent

highly-flammableni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#leichtentflammbar

belongs to
FireBehaviour c
has facts
isMoreFlammableThan op normal-flammable

Hospitalityni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Hospitality

belongs to
Hospitality c
is also defined as
class

Institutionni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Institution

belongs to
Institution c
is also defined as
class

Kindergardenni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Kindergarden

belongs to
Kindergarden c
is also defined as
class

Kitchenni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Kitchen

belongs to
Kitchen c
is also defined as
class

Labni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Lab

belongs to
Lab c
is also defined as
class

LawEnforcementni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#LawEnforcement

belongs to
LawEnforcement c
is also defined as
class

Leisureni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Leisure

belongs to
Leisure c
is also defined as
class

LivingRoomni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#LivingRoom

belongs to
LivingRoom c
is also defined as
class

MeetingRoomni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#MeetingRoom

belongs to
MeetingRoom c
is also defined as
class

mosthighly-fire-resistantni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#höchstfeuerbeständig

belongs to
FireResistance c
has facts
isMoreFireResistantThan op highly-fire-resistant

non-flammableni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#nichtbrennbar

belongs to
FireBehaviour c

normal-flammableni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#normalentflammbar

belongs to
FireBehaviour c
has facts
isMoreFlammableThan op retardent-flammable

OfficeRoomni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#OfficeRoom

belongs to
OfficeRoom c
has facts
usesGrossFloorArea dp "600.0"^^double
is also defined as
class

OtherRoomUsageni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#OtherRoomUsage

belongs to
OtherRoomUsage c
is also defined as
class

OvernightAccommodationni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#OvernightAccommodation

belongs to
OvernightAccommodation c
is also defined as
class

Parkingni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Parking

belongs to
Parking c
is also defined as
class

Residentialni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Residential

belongs to
Residential c
is also defined as
class

retardent-flammableni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#schwerentflammbar

belongs to
FireBehaviour c
has facts
isMoreFlammableThan op non-flammable

Salesni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Sales

belongs to
Sales c
is also defined as
class

SalesRoomni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#SalesRoom

belongs to
SalesRoom c
is also defined as
class

SceneAreani back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#SceneArea

belongs to
SceneArea c
is also defined as
class

SpectatorFacilityni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#SpectatorFacility

belongs to
SpectatorFacility c
is also defined as
class

Sportni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Sport

belongs to
Sport c
is also defined as
class

StairSpaceni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#StairSpace

belongs to
StairSpace c
is also defined as
class

Storageni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Storage

belongs to
Storage c
is also defined as
class

StoreStreetni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#StoreStreet

belongs to
StoreStreet c
is also defined as
class

Technologyni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Technology

belongs to
Technology c
is also defined as
class

tor01ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Tor01

belongs to
Gate c
has facts
isSelfClosing dp "true"^^boolean
isTightClosing dp "true"^^boolean

tor02ni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Tor02

belongs to
Gate c
has facts
hasFireResistance op fire-retardent
isSelfClosing dp "true"^^boolean
isTightClosing dp "true"^^boolean

TypeFireWallni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#BauartBrandwand

belongs to
SpaceClosure c

WithoutRequirementni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#ohneAnforderung

belongs to
SpaceClosure c

Workni back to ToC or Named Individual ToC

IRI: https://purl.org/fisa#Work

belongs to
Work c
is also defined as
class

Legend back to ToC

c: Classes
op: Object Properties
dp: Data Properties
ni: Named Individuals

Acknowledgments back to ToC

The authors would like to thank Silvio Peroni for developing LODE, a Live OWL Documentation Environment, which is used for representing the Cross Referencing Section of this document and Daniel Garijo for developing Widoco, the program used to create the template used in this documentation.